49 CFR Appendix A to Part 223 - Appendix A to Part 223—Certification of Glazing Materials
As provided in this part, certified glazing materials installed in locomotives, passenger cars, or cabooses must be certified by the glazing manufacturer in accordance with the following procedures:
a. General Requirements
(1) Each manufacturer that provides glazing materials, intended by the manufacturer for use in achieving compliance with the requirements of this part, shall certify that each type of glazing material being supplied for this purpose has been succcessfully tested in accordance with this appendix and that test verification data is available to a railroad or to FRA upon request.
(2) The test verification data shall contain all pertinent original data logs and documentation that the selection of material samples, test set-ups, test measuring devices, and test procedures were performed by qualified personnel using recognized and acceptable practices and in accordance with this appendix.
b. Testing Requirements
(1) The material to be tested (Target Material) shall be a full scale sample of the largest dimension intended to be produced and installed.
(2) The Target Material shall be representative of production material and shall be selected on a documented random choice basis.
(3) The Target Material shall be securely and rigidly attached in a fixture so that the fixture's own characteristics will not induce test errors.
(4) The Target Material so selected and attached shall constitute a Test Specimen.
(5) The Test Specimen will then be equipped with a Witness Plate that shall be mounted parallel to and at a distance of six inches in back of the Target Material. The Witness Plate shall have at least an area which will cover the full map of the Target Material.
(6) The Witness Plate shall be an unbacked sheet of maximum 0.006-inch, alloy 1100 temper O, aluminum stretched within the perimeter of a suitable frame to provide a taut surface. If a steel ball is used for Large Object Impact testing, the Witness Plate shall be an unbacked sheet of maximum 0.002-inch, alloy 1145 temper H19 or equivalent, aluminum stretched within the perimeter of a suitable frame to provide a taut surface.
(7) The Test Specimen will be positioned so that the defined projectile impacts it at an angle of 90 degrees to the Test Specimen surface.
(8) The point of impact of the defined projectile will be within a radius of 3″ of the centroid of the Target Material.
(9) Velocity screens or other suitable velocity measuring devices will be positioned so as to measure the impact velocity of the defined projectile within a 10% accuracy tolerance, with test modifications made to guarantee that the stipulated minimum velocity requirements are met.
(10) The Test Specimen for glazing material that is intended for use in end facing glazing locations shall be subjected to a Type I test regimen consisting of the following tests:
(i) Ballistic Impact: A standard 22 caliber long rifle lead bullet of 40 grains in weight impacts at a minimum velocity of 960 feet per second.
(ii) Large Object Impact:
(A) A cinder block weighing a minimum of 24 lbs with dimensions of 8 inches by 8 inches by 16 inches nominally impacts the glazing surface at the corner of the block at a minimum velocity of 44 feet per second. The cinder block must be of composition making it structurally sound, such as referenced in ASTM, International (ASTM) Specification C33 or ASTM C90; or
(B) A steel ball (e.g., ball bearing or shot put) weighing a minimum of 12 lbs impacts the glazing surface at a minimum velocity of 62.5 feet per second.
(11) The Test Specimen for glazing material that is intended for use only in sidefacing glazing locations shall be subjected to a Type II test regimen consisting of the following tests:
(i) Ballistic Impact: A standard 22 caliber long rifle lead bullet of 40 grains in weight impacts at a minimum velocity of 960 feet per second.
(ii) Large Object Impact:
(A) A cinder block weighting a minimum of 24 lbs with dimensions of 8 inches by 8 inches by 16 inches nominally impacts the glazing surface at the corner of the block at a minimum velocity of 12 feet per second. The cinder block must be of composition making it structurally sound, such as referenced in ASTM C33-18 or ASTM C90; or
(B) A solid steel ball (e.g., ball bearing or shot put) weighing a minimum of 12 lbs impacts the glazing surface at a minimum velocity of 17 feet per second.
(12) Three different test specimens must be subjected to the ballistic impact portion of these tests.
(13) Except as provided in paragraphs b.(10)(ii)(B) and b.(11)(ii)(B) of this appendix, two different test specimens must be subjected to the large object impact portion of the tests. For purposes of paragraphs b.(10)(ii)(B) and b.(11)(ii)(B), four different test specimens shall be subjected to each impact test.
(14) A material so tested must perform so that:
(i) there shall be no penetration of the back surfaces (side closest to Witness Plate) of the Target Material by the projectile. Partial penetration of the impact (front) surface of the Target Material does not constitute a failure; and
(ii) there shall be no penetration of particles from the back side of the Target Material through the back side of the prescribed Witness Plate.
(15) Except as provided in paragraphs b.(10)(ii)(B) and b.(11)(ii)(B) of this appendix, test specimens must consecutively pass the required number of tests at the required minimum velocities. Individual tests resulting in failures at greater than the required minimum velocities may be repeated but a failure of an individual test at less than the minimum velocity shall result in termination of the total test and failure of the material. For purposes of paragraphs b.(10)(ii)(B) and b.(11)(ii)(B), three out of four test specimens must pass the test for the glazing material to be acceptable. Individual tests resulting in a failure at velocities above the prescribed range may be repeated.
(16) After successful completion of the prescribed set of required consecutive tests, a manufacturer may certify in writing that a particular glazing material meets the requirements of these standards.
c. Material Identification
(1) Each individual unit of glazing material shall be permanently marked, prior to installation, to indicate that this type of material has been successfully tested as set forth in this appendix and that marking shall be done in such a manner that it is clearly visible after the material has been installed.
(2) Each individual unit of a glazing material that has successfully passed the Type I testing regimen shall be marked to indicate:
(i) “FRA Type I” material;
(ii) the manufacturer of the material;
(iii) the type or brand identification of the material.
(3) Each individual unit of a glazing material that has successfully passed the Type II testing regimen shall be marked to indicate:
(i) “FRA Type II” material;
(ii) the manufacturer of the material;
(iii) the type or brand identification of the material.