Ala. Admin. Code r. 535-X-11-.07 - Construction Plan Requirements
(1) Manufacturers
making application for plan review will be required to submit plans showing all
elements relating to a specific basic model on a sheet or sheets properly
identifiable as such. Any alternate method of construction to the basic model
(structural, plumbing, mechanical, or electrical) must be shown on separate
plan sheets and also be identifiable as such.
(2) The manufacturer or a legally constituted
officer must submit a written statement in letter form and notarized that the
manufacturer is manufacturing according to the plans submitted to the
Commission.
(3) Complete plans and
specifications are to be submitted with the stamp and written signature of a
registered architect and registered engineer as required by the rules of the
Board of Registration of Architects and the Alabama Board of Engineers. A
written statement in letter form and notarized shall be included with the
submittal requirements stating that the registered professional has drawn the
plans according to the codes adopted by the Commission.
(4) All copies of plans shall indicate the
manufacturer's name, address, and location.
(5) Indicate or designate all work to be
performed on site, including connections of all systems.
(6) All plan drawings must:
(a) Provide details for and show method of
field connection of units or modules to each other and foundations.
(b) Show all exterior elevations.
(c) Provide elevations and details of
elevations, walls, or sections thereof providing resistance to vertical loads
or lateral forces.
(d) Provide a
complete floor plan and floor framing plan.
(e) Provide complete details of the framing
system showing direction of face grain of plywood, blocking, connections,
etc.
(f) Provide vertical load
calculations.
(g) Provide lateral
force calculations and indicate maximum wind speed.
(h) Provide complete details of all
structural connections such as chord splices, corner and wall intersection
details, post and beam connections, beam splices, etc. Both in-plant and
on-site connections must be shown.
(i) Provide complete roof framing plan
showing method of framing, direction of face grain of plywood, connections,
etc. Show roof covering material and roofing specifications on
drawings.
(j) Provide cross
sections as necessary to identify major building components.
(k) Provide information on plans for plywood
when used, such as thickness, index number, grade, etc. Lumber grades should
also be listed using the national design specifications for stress grade lumber
and its fastenings.
(l) Indicate
details of flashing, such as at openings and at penetrations through roof.
Indicate flashing material and gauge to be used.
(m) Show attic access and attic
ventilations.
(n) Indicate exterior
wall and soffit material as well as finish.
(o) Indicate interior wall and ceiling
finish.
(p) Provide fire separation
details, where required by code.
(q) Show opening treatment for doors and
windows including door swings.
(r)
Show all foundation vents and under floor access when an element of
manufactured building.
(s) Describe
all structural steel materials, sizes, finish, and connection details in
accordance with the American Institute of Steel Construction Design
Manual.
(t) Describe all
reinforcing, concrete and mesh materials, strengths, grades, sizes, spacings,
and details in accordance with American Concrete Institute Building Code AC
318-71.
(u) All drawings must be
noted as to all work that is required on the job site.
Notes
Author: Elwyn Thomas
Statutory Authority: Code of Ala. 1975, ยงยง 24-4A-3, 24-6-4.