Cal. Code Regs. Tit. 22, § 64677 - Sample Collection Methods for Taps
(a) All tap samples for lead and copper
collected pursuant to this chapter, with the exception of lead service line
samples collected under section
64689 (Lead Service Line Sampling)
and samples collected under subsection (d), shall be first-draw samples,
pursuant to subsection (b).
(b) A
first-draw sample shall be one liter in volume and have stood motionless in the
plumbing system of each site for at least six hours, but not more than twelve.
Samples from residential housing shall be collected from the cold-water kitchen
tap or bathroom sink tap. Samples from a non-residential building shall be
collected at an interior tap from which water is typically drawn for
consumption. Samples may be collected by the system or the system may allow
residents to collect tap samples after instructing the residents of the
sampling procedures specified in this section. To avoid problems of residents
handling nitric acid, acidification of samples may be done up to 14 days after
collection. After acidification to resolubilize the metals, the sample shall
stand in the original container for the time specified by the method used
pursuant to section
64670(c) before
it can be analyzed. If a system allows residents to perform sampling, the
system may not challenge, based on alleged errors in sample collection, the
accuracy of sampling results.
(c) A
system shall collect each tap sample from the same site from which it collected
a sample during the previous period. If the system cannot gain entry to a site
in order to collect a tap sample, it may collect the tap sample from another
site in its sampling pool as long as the new site meets the same criteria, and
is as close as possible to the original site.
(d) A system that does not have enough taps
to supply first-draw samples may apply to the Department in writing to
substitute non-first-draw samples. Such systems shall collect as many
first-draw samples as possible and identify sampling times and locations that
would likely result in the longest standing time for the remaining
sites.
Notes
2. Refiling of 12-11-95 order, including amendment of NOTE, filed 4-9-96 as an emergency; operative 4-10-96 (Register 96, No. 15). A Certificate of Compliance must be transmitted to OAL by 8-8-96 or emergency language will be repealed by operation of law on the following day.
3. Certificate of Compliance as to 12-11-95 order, including amendment of subsection (a), transmitted to OAL 8-7-96 and filed 9-16-96 (Register 96, No. 38).
4. Repealer of article 3 (sections 64677-64678) and repealer and new section filed 9-11-2003; operative 10-11-2003 (Register 2003, No. 37).
Note: Authority cited: Sections 100275, 116350, 116365, 116375 and 116385, Health and Safety Code. Reference: Sections 116325- 116750, Health and Safety Code.
2. Refiling of 12-11-95 order, including amendment of Note, filed 4-9-96 as an emergency; operative 4-10-96 (Register 96, No. 15). A Certificate of Compliance must be transmitted to OAL by 8-8-96 or emergency language will be repealed by operation of law on the following day.
3. Certificate of Compliance as to 12-11-95 order, including amendment of subsection (a), transmitted to OAL 8-7-96 and filed 9-16-96 (Register 96, No. 38).
4. Repealer of article 3 (sections 64677-64678) and repealer and new section filed 9-11-2003; operative 10-11-2003 (Register 2003, No. 37).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.