Cal. Code Regs. Tit. 3, § 582 - Operators of Pasteurization Equipment
All persons operating pasteurizers must comply with the following:
(a) Every pasteurizer must
be equipped and operated with a recording thermometer which must be used solely
for that individual piece of equipment. Transferring of thermometer spuds from
one vat to another is prohibited.
(b) Recording of temperatures on recording
thermometer charts shall be continued during the complete revolution of the
chart and in no case shall a recording thermometer chart be used for a period
longer than for which it was intended.
(c) Recording thermometer charts shall be
placed on recording thermometer devices in a way that will record the correct
time of day during which the various operations of pasteurization, cooling (if
cooled in vat) and sterilization took place.
(d) Recording thermometer charts shall be
dated at the time they are placed on recording thermometer devices.
(e) Notations shall be placed on recording
thermometer charts showing what product or products were pasteurized.
(f) All recording thermometer devices shall
be securely fastened to solid foundations and shall be free from
vibration.
(g) All recording
thermometer charts shall be authenticated by the signature of the operator of
the pasteurizing equipment.