Cal. Code Regs. Tit. 8, div. 1, ch. 4, subch. 4, app B, Plate B-30-a - Safe Lateral Strength and Required Penetration of Common Wire Nails
Driven Perpendicular to Grain of the Wood
Loads (pounds) | |||||||||
Size of nail | Standard length (inches) | Wire gauge | Penetration required (inches) | Douglas fir or southern pine | Redwood | Other species | |||
6d .......................... | 2 | 11 1/2 | 1 | 70 | 58 | As | |||
8d .......................... | 2 1/2 | 10 1/4 | 1 1/4 | 100 | 82 | determined | |||
10d .......................... | 3 | 9 | 1 1/2 | 120 | 98 | by the | |||
12d .......................... | 3 1/4 | 9 | 1 5/8 | 130 | 106 | enforcing | |||
16d .......................... | 3 1/2 | 8 | 1 5/8 | 160 | 123 | agency | |||
20d .......................... | 4 | 6 | 2 | 190 | 155 | ||||
30d .......................... | 4 1/2 | 5 | 2 1/4 | 230 | 188 | ||||
40d .......................... | 5 | 4 | 2 1/2 | 270 | 220 | ||||
50d .......................... | 5 1/2 | 3 | 2 3/4 | 310 | 250 | ||||
60d .......................... | 6 | 2 | 3 | 360 | 295 |
(2) Safe Resistance to Withdrawal. A wire nail driven perpendicular to grain of the wood shall not be subjected to a greater load, tending to cause withdrawal, than the safe resistance of the nail to withdrawal, as set forth in Plate B-30-b.
Nails driven parallel to grain of the wood shall not be allowed for resisting withdrawal forces.