Cal. Code Regs. Tit. 8, div. 1, ch. 4, subch. 4, app B, Plate B-30-a - Safe Lateral Strength and Required Penetration of Common Wire Nails

Driven Perpendicular to Grain of the Wood

Loads (pounds)
Size of nail Standard length (inches) Wire gauge Penetration required (inches) Douglas fir or southern pine Redwood Other species
6d .......................... 2 11 1/2 1 70 58 As
8d .......................... 2 1/2 10 1/4 1 1/4 100 82 determined
10d .......................... 3 9 1 1/2 120 98 by the
12d .......................... 3 1/4 9 1 5/8 130 106 enforcing
16d .......................... 3 1/2 8 1 5/8 160 123 agency
20d .......................... 4 6 2 190 155
30d .......................... 4 1/2 5 2 1/4 230 188
40d .......................... 5 4 2 1/2 270 220
50d .......................... 5 1/2 3 2 3/4 310 250
60d .......................... 6 2 3 360 295
(2) Safe Resistance to Withdrawal. A wire nail driven perpendicular to grain of the wood shall not be subjected to a greater load, tending to cause withdrawal, than the safe resistance of the nail to withdrawal, as set forth in Plate B-30-b.

Nails driven parallel to grain of the wood shall not be allowed for resisting withdrawal forces.

Notes

Cal. Code Regs. Tit. 8, div. 1, ch. 4, subch. 4, app B, Plate B-30-a