Cal. Code Regs. Tit. 8, § 1624 - Runways for Foot Traffic
(a)
Except as provided elsewhere, ramps or runways erected for the use of workmen
shall be not less than 20 inches in width, and shall be secured and supported
so as to avoid deflection and springing action.
(b) Securely fastened cleats or other means
shall be used on inclined runways sloped two feet in 10 feet or more to improve
the footing. Where cleats are used, they shall be eight inches or more in
length and not more than 16 inches apart.
(c) When planks are used for raised walkways,
runways, or sidewalks, they shall be secured against displacement. Planks shall
be uniform in thickness and all exposed ends shall be provided with beveled
cleats to prevent tripping.
EXCEPTION: The use of beveled cleats on scaffold platforms is not required.
Notes
2. Amendment filed 5-21-75; effective thirtieth day thereafter (Register 75, No. 21).
3. Repealer and new subsection (c) filed 3-19-79; effective thirtieth day thereafter (Register 79, No. 12).
4. Amendment of subsection (b) filed 1-14-86; effective thirtieth day thereafter (Register 86, No. 3).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
2. Amendment filed 5-21-75; effective thirtieth day thereafter (Register 75, No. 21).
3. Repealer and new subsection (c) filed 3-19-79; effective thirtieth day thereafter (Register 79, No. 12).
4. Amendment of subsection (b) filed 1-14-86; effective thirtieth day thereafter (Register 86, No. 3).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.