Cal. Code Regs. Tit. 8, § 3085.6 - Counterweights [Rule 1500.5]
(a) Where a counterweight runway is not in
the same hoistway as the car, an enclosure meeting the requirements of Section
3085.1 shall be provided.
(b) Access shall be provided for inspection,
maintenance and repair of an enclosed counterweight and its ropes. Doors in the
counterweight enclosures shall be self-closing and shall be provided with:
(1) An electric contact, the opening of which
will remove power from the elevator driving machine motor and brake;
and
(2) A self-locking keyed
tumbler lock. [1500.5b]
Notes
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.