Cal. Code Regs. Tit. 8, § 3090 - Escalator Machinery and Equipment
EXCEPTION to 3090 (a)(3), (4), (5):
Each escalator shall be provided with an electrically released mechanically applied brake capable of stopping the up or down traveling escalator with any load up to rated load, as defined in subsection 3089(j). This brake shall be located either on the driving machine or on the main drive shaft.
Where a chain is used to connect the driving machine to the main drive shaft, a brake shall be provided on the driven shaft. It is not required that this brake be of the electrically released type if an electrically released brake is provided on the driving machine.
EXCEPTION: The overspeed governor is not required where a low slip alternating current squirrel cage induction motor is used and the motor is directly connected to the driving machine.
EXCEPTION: Machinery space in which main line disconnect switch is located.
(Title 24, Part 7, Section 7-3090.)
Notes
2. Amendment of subsections (a) and (b) filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 35).
3. Editorial correction of printing error in subsection (b)(1)(B) (Register 94, No. 18).
4. Amendment of subsection (d) filed 6-29-94; operative 7-29-94 (Register 94, No. 26).
5. Amendment of subsections (c)-(c)(1) and new subsection (c)(2) filed 12-6-94; operative 1-5-95 (Register 94, No. 49).
Note: Authority cited: Labor Code Section 142.3. Reference: Labor Code Section 142.3.
2. Amendment of subsections (a) and (b) filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 35).
3. Editorial correction of printing error in subsection (b)(1)(B) (Register 94, No. 18).
4. Amendment of subsection (d) filed 6-29-94; operative 7-29-94 (Register 94, No. 26).
5. Amendment of subsections (c)-(c)(1) and new subsection (c)(2) filed 12-6-94; operative 1-5-95 (Register 94, No. 49).
Group II regulations apply to existing elevators installed prior to October 25, 1998. Italicized paragraphs, sentences, or phrases apply to all existing elevators while non-italicized apply to elevators installed after 1970 or after the date the regulation was adopted.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.