Cal. Code Regs. Tit. 8, § 3100 - Rated Load of Passenger Elevators
W = (2A2/3) + (200A/3).
W = 7A2/150) + (125A - 1367).
Where W = Minimum rated load in pounds, and A = inside net platform area in square feet.
Click here to view image
Minimum Rated Loads for Passenger Elevators
FIGURE 3100 A1
Westlaw Tabular or graphic material set at this point is not displayable. |
Minimum Rated Loads for Passenger Elevators
FIGURE 3100 A2
Westlaw Tabular or graphic material set at this point is not displayable. |
Minimum Rated Loads for Passenger Elevators
FIGURE 3100 A3
(Title 24, Part 7, Section 7-3100)
Notes
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
Group II regulations apply to existing elevators installed prior to October 25, 1998. Italicized paragraphs, sentences, or phrases apply to all existing elevators while non-italicized apply to elevators installed after 1970 or after the date the regulation was adopted.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.