Cal. Code Regs. Tit. 8, § 3127.5 - Operating and Safety Devices
Operating and safety devices shall comply with Section 905 of ASME A17.1-1996, except for Rule 905.3k(1), which is hereby incorporated by reference.
(a) Means shall be provided which will cause the opening of the power circuit to the escalator driving machine motor and brake if a horizontal force exceeding 400 lb/ft in the direction of travel is applied at either side, or exceeding 800 lb/ft at the center of the front edge of the combplate.
(Title 24, Part 7, Section 7-3127.5.)
Notes
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code; and Section 18943(b), Health and Safety Code.
Group III regulations apply to new elevators installed after October 25, 1998.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.