Cal. Code Regs. Tit. 8, § 797 - Example of the Application and Explanation of Patch Tables and Charts
Referring to Table 1, it is found that seven-sixteenths-inch (7/16") plate with fifteen-sixteenths-inch (15/16") diameter rivet holes, pitched two and one-fourth (2 1/4) gives a seam efficiency of fifty-six percent (56%).
Referring to Table 2, E = 0.74 and e = 0.56 gives a constant C = 1.75; then width W = L x C = 36 x 1.75 = sixty-three inches (63").
A crescent-shaped patch has already been installed on a horizontal tubular boiler. It is thirty inches (30") long and forty-eight inches (48") wide. The seam is single riveted with thirteen-sixteenths-inch (13/16") rivet holes pitched one and fifteen-sixteenths inches (1 15/16"). The boiler shell plate is three-eighths-inch (3/8") thick. The longitudinal seam is of the double-riveted butt-strap type having an efficiency of eighty-two percent (82%). The safety valve is set for one hundred twenty-five pounds (125#) pressure. What maximum pressure should be allowed on the boiler? Reference to Table 1, shows that the normal efficiency of the patch seam is fifty-seven percent (57%). (If the efficiency is not found in the Table, refer to any other available table or determine it in the manner described in paragraphs A-1, A-2 and A-3 of the Appendix of the A.S.M.E. Boiler Code.)
Divide the width of the patch, W = forty-eight inches (48") by the length, L = thirty inches (30") to find the constant, C = 48/30 = 1.60. Follow down column 0.57 of Table 2 until 1.60 is found. It will be noted that this is somewhere between 1.56 and 1.62 representing E somewhere between 0.72 and 0.73. As the difference between 1.56 and 1.62 is 6, and the difference between 1.56 and 1.60 is 4, E will be 0.72 plus 4/6 of 0.01 which is 0.7266.
The maximum allowable working pressure varies directly as the seam efficiency. Accordingly, P = (0.7266/0.82) x 125 = 110#. If this pressure allowance interferes with the operation of the plant, the patch shall be replaced by a new one with the proper dimensions giving a diagonal efficiency of eighty-two percent (82%).
Reference to Table 1 shows that a single-riveted lap seam with seven-sixteenths-inch (7/16") plate, fifteen-sixteenths-inch (15/16") diameter rivet holes, and two-and-one-half-inch (2 1/2") pitch has a normal efficiency of fifty-six percent (56%).
Reference to Table 3, shows E = 0.82 and e = 0.56, the constant C is 3.16.
Then width W = C x 1 / 2.
W = 3.16 x 36 / 2 = 56.88 or practically fifty-seven inches (57").
Click here to view image
Click here to view image
Click here to view image
Click here to view image
Notes
2. Change without regulatory effect repealing and adopting new Figures 1-6 within subsection (b) filed 5-19-2008 pursuant to section 100, title 1, California Code of Regulations (Register 2008, No. 21).
2. Change without regulatory effect repealing and adopting new Figures 1-6 within subsection (b) filed 5-19-2008 pursuant to section 100, title 1, California Code of Regulations (Register 2008, No. 21).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.