2 CCR 407-6-5 - VENTILATION
1. Air in all
active working and all other areas of the tourist mine where people are
required to work or travel shall contain at least 19.5% volume percent oxygen.
To assure 19.5% volume percent oxygen is maintained, a test will be taken with
a calibrated electronic oxygen meter. In addition to the electronic oxygen
meter, a flame safety lamp may be used as a backup measuring device.
2. All underground main fans shall have
controls placed at a suitable protected location remote from the fan and
preferably on the surface.
3. When
auxiliary fan systems are used, such systems shall minimize recirculation and
be maintained to provide ventilation air that effectively sweeps the affected
area.
4. Unventilated areas shall
be sealed or barricaded and posted against entry.
5. Unless an approved method of detecting
hydrogen gas is available, all battery charging stations will either be located
on the surface or will be ventilated directly to the surface with a sufficient
volume of air to prevent the accumulation of hydrogen gas.