4 CCR 723-3-3880 - Production Data
(a) The CSG owner
shall pay for a production meter to be used to measure the amount of
electricity and RECs generated by each CSG whether installed by the utility or
the CSG owner. A net meter can serve as the production meter if the utility
determines that there is no material onsite load at the CSG facility.
(b) The owner of a CSG with a nameplate
rating of one MW AC or greater shall register the CSG and report the CSG's
production data to the WREGIS in accordance with paragraph 3659(j).
(c) CSGs are required to provide real time
reporting of production as specified by the utility. For CSGs greater than 250
kW AC, the CSG owner shall provide real time electronic access to production
and system operation data. In the event that a CSG greater than 250 kW AC also
collects meteorological data, the CSG owner shall provide, at the utility's
request, real time electronic access to the utility to such meteorological
data. A utility may require different real time reporting for CSGs 250 kW AC
and smaller.
(d) Production from
the CSG shall be reported by the CSG subscriber organization to its CSG
subscribers at least monthly. To facilitate the tracking of production data by
CSG subscribers, CSG owners or CSG subscriber organizations are encouraged to
provide website access to subscribers showing real time output from the CSG, if
practicable, as well as historical production data.