7 CCR 1101-9-6-6 - Use of Detonating Cord
(A) Care shall
be taken to select a detonating cord consistent with the type and physical
condition of the borehole and stemming and the type of explosives
used.
(B) Detonating cord shall be
handled and used with the same respect and care given other
explosives.
(C) If using a
detonating type cord for blasting, the double-trunkline or loop systems shall
be used.
(D) In multiple-row
blasts, the trunkline layout shall be designed so that the detonation can reach
each blast hole from at least two directions.
(E) All detonating cord knots shall be tight
and all connections shall be kept at right angles to the trunklines.
(F) The line of detonating cord extending out
of a borehole or from a charge shall be cut from the supply spool before
loading the remainder of the bore hole or placing additional charges.
(G) Detonating cord shall be handled and used
with care to avoid damaging or severing the cord during and after loading and
hooking-up.
(H) Detonating cord
connections shall be made in accordance with the manufacturer's recommended
methods. Knot-type or other cord-to-cord connections shall be made only with
detonating cord in which the explosive core is dry.
(I) Detonating cord shall be cut with a sharp
knife, razor blade or cutters designed for use with detonating cord. Scissors
or plier type cutters shall not be used.
(J) All detonating cord trunklines and branch
lines shall be free of loops, sharp kinks, or angles that direct the cord back
toward the oncoming line of detonation.
(K) All detonating cord connections shall be
inspected before firing the blast.
(L) When detonating cord millisecond-delay
connectors or short-interval-delay electric detonators are used with detonating
cord, the practice shall conform strictly to the manufacturer's
recommendations.
(M) When
connecting a detonator to detonating cord, the detonator shall be taped or
otherwise attached securely along the side or the end of the detonating cord,
with the end of the detonator containing the explosive charge pointed in the
direction in which the detonation is to proceed.
(N) When initiating detonating cord with fuse
detonators and safety fuse, two fuse detonators shall be required.
(O) Detonators for firing the trunkline shall
not be brought to the loading area nor attached to the detonating cord until
the area has been cleared for the blast.