An SQG may accumulate hazardous waste on site without a
permit or interim status, and without complying with the requirements of 35
Ill. Adm. Code 702, 703, 705, and 724 through 727, or the notification
requirements of section 3010 of RCRA (42 USC
6930), provided that all of the following
conditions for exemption listed in this Section are met:
b) Accumulation. The generator must
accumulate hazardous waste on site for no more than 180 days, unless in
compliance with the conditions for exemption allowing longer accumulation in
subsections (d) and (e). The following accumulation conditions also apply:
1) Accumulation Limit. The quantity of
hazardous waste accumulated on site must never exceed 6,000 kg (13,200
lbs);
2) Accumulation of Hazardous
Waste in Containers
A) Condition of
Containers. If a container holding hazardous waste is not in good condition or
the container begins to leak, the SQG must immediately transfer the hazardous
waste from this container to a container that is in good condition or
immediately manage the waste in some other way that complies with the
conditions for exemption of this Section.
B) Compatibility of Waste with Container. The
SQG must use a container made of or lined with materials that will not react
with and that are otherwise compatible with the hazardous waste to be
accumulated, so that the ability of the container to contain the waste is not
impaired.
C) Management of
Containers
i) A container holding hazardous
waste must always be closed during accumulation, except when it is necessary to
add or remove waste.
ii) A
container holding hazardous waste must not be opened, handled, or accumulated
in a manner that may rupture the container or cause it to leak.
D) Inspections. At least weekly,
the SQG must inspect central accumulation areas. The SQG must look for leaking
containers and for deterioration of containers caused by corrosion or other
factors. See subsection (b)(2)(A) for remedial action required if deterioration
or leaks are detected.
E) Special
Conditions for Accumulation of Incompatible Wastes
i) The SQG must not place incompatible wastes
or incompatible wastes and materials (for examples, see appendix V to 40 CFR
265, incorporated by reference in 35 Ill. Adm. Code
720.111) must not be
placed in the same container, unless the generator complies with 35 Ill. Adm.
Code
725.117(b).
ii) The SQG must not place hazardous waste in
an unwashed container that previously held an incompatible waste or material
(for examples, see appendix V to 40 CFR
265, incorporated by reference in 35
Ill. Adm. Code
720.111), unless the generator complies with 35 Ill. Adm. Code
725.117(b).
iii) The SQG must separate or protect a
container accumulating hazardous waste, by means of a dike, berm, wall, or
other device, from any waste or other materials accumulated or stored nearby in
other containers, piles, open tanks, or surface impoundments.
3) Accumulation of
Hazardous Waste in Tanks
A) This subsection
(b)(3)(A) corresponds with 40 CFR
262.116(b)(3)(i), which USEPA has marked
"reserved". This statement maintains structural consistency with the
corresponding federal regulation.
B) An SQG of hazardous waste must comply with
the following general operating conditions:
i) Treatment or accumulation of hazardous
waste in tanks must comply with 35 Ill. Adm. Code
725.117(b).
ii) The SQG must not place hazardous wastes
or treatment reagents in a tank if the hazardous wastes or treatment reagents
could cause the tank or its inner liner to rupture, leak, corrode, or otherwise
fail before the end of its intended life.
iii) The SQG must operate uncovered tanks
must be operated to ensure at least 60 centimeters (2 feet) of freeboard,
unless the tank is equipped with a containment structure (e.g., dike or
trench), a drainage control system, or a diversion structure (e.g., standby
tank) with a capacity that equals or exceeds the volume of the top 60
centimeters (2 feet) of the tank.
iv) If hazardous waste is continuously fed
into a tank, the SQG must equip the tank with a means to stop this inflow
(e.g., waste feed cutoff system or by-pass system to a
stand-by tank).
C)
Except as noted in subsection (b)(3)(iv), an SQG that accumulates hazardous
waste in tanks must inspect each of the following, if present:
i) Discharge control equipment (e.g., waste
feed cutoff systems, by-pass systems, and drainage systems) at least once each
operating day, to ensure that it is in good working order;
ii) Data gathered from monitoring equipment
(e.g., pressure and temperature gauges) at least once each operating day, to
ensure that the tank is being operated according to its design;
iii) The level of waste in the tank at least
once each operating day, to ensure compliance with subsection
(b)(3)(ii)(C);
iv) The construction
materials of the tank at least weekly, to detect corrosion or leaking of
fixtures or seams; and
v) The
construction materials of discharge confinement structures and the immediately
surrounding area (e.g., dikes) at least weekly, to detect erosion or obvious
signs of leakage (e.g., wet spots or dead vegetation). The SQG must remedy any
deterioration or malfunction of equipment or structures that the inspection
reveals on a schedule that ensures that the problem does not lead to an
environmental or human health hazard. If a hazard is imminent or has already
occurred, the SQG must immediately take remedial action.
D) A SQG accumulating hazardous waste in
tanks or tank systems that have full secondary containment and that either use
leak detection equipment to alert personnel to leaks, or implement established
workplace practices to ensure leaks are promptly identified, must inspect at
least weekly, if applicable, the areas identified in subsections (b)(3)(C)(i)
through (b)(3)(C)(v). Use of the alternate inspection schedule must be
documented in the generator's operating record. This documentation must include
a description of the established workplace practices at the SQG.
E) This subsection (b)(3)(E) corresponds with
40 CFR
262.116(b)(3)(v), which USEPA has marked "reserved". This statement
maintains structural consistency with the corresponding federal
regulation.
F) An SQG accumulating
hazardous waste in tanks must remove all hazardous waste from tanks, discharge
control equipment, and discharge confinement structures upon closure of the
facility. At closure, as throughout the operating period, unless the SQG can
demonstrate, in accordance with 35 Ill. Adm. Code
721.103(c) or
(d), that any solid waste removed from its
tank is not a hazardous waste, then it must manage such waste in accordance
with all applicable provisions of this Part and 35 Ill. Adm. Code
722,
723,
725
and
728.
G) An SQG must comply with
the following special conditions for accumulation of ignitable or reactive
waste:
i) Ignitable or reactive waste must
not be placed in a tank, unless the waste is treated, rendered, or mixed before
or immediately after placement in a tank so that the resulting waste, mixture,
or dissolution of material no longer meets the definition of ignitable or
reactive waste under 35 Ill. Adm. Code
721.121
or
721.123,
and the SQG complies with 35 Ill. Adm. Code
725.117(b);
the generator accumulates or treats the waste is in such a way that the waste
is protected from any material or conditions that may cause it to ignite or
react; or the SQG uses the tank solely for emergencies.
ii) An SQG that treats or accumulates
ignitable or reactive waste in covered tanks must comply with the buffer zone
requirements for tanks contained in NFPA 30 (1977 or 1981), incorporated by
reference in 35 Ill. Adm. Code
720.111.
iii) An SQG must not place incompatible
wastes, or incompatible wastes and materials (for examples, see appendix V to
40 CFR
265, incorporated by reference in 35 Ill. Adm. Code
720.111) in the same
tank or place hazardous waste in an unwashed tank that previously held an
incompatible waste or material, unless the generator complies with 35 Ill. Adm.
Code
725.117(b).
4) Accumulation of
Hazardous Waste on Drip Pads. If the waste is placed on drip pads, the SQG must
comply with the following:
A) Subpart W of 35
Ill. Adm. Code
725 (except 35 Ill. Adm. Code
725.545(c)
);
B) The SQG must remove all
wastes from the drip pad at least once every 90 days. Any hazardous wastes that
the generator removes from the drip pad are then subject to the 180-day
accumulation limit in subsection (b) and Section
722.115
if hazardous wastes are being managed in satellite accumulation areas prior to
being moved to the central accumulation area; and
C) The SQG must maintain on site at the
facility the following records readily available for inspection:
i) A written description of procedures that
are followed to ensure that all wastes are removed from the drip pad and
associated collection system at least once every 90 days; and
ii) Documentation of each waste removal,
including the quantity of waste removed from the drip pad and the sump or
collection system and the date and time of removal.
5) Accumulation of Hazardous Waste
in Containment Buildings. If the SQG places waste in containment buildings, the
SQG must comply with Subpart DD of 35 Ill. Adm. Code
725. The SQG must label
its containment buildings with the words "Hazardous Waste" in a conspicuous
place easily visible to employees, visitors, emergency responders, waste
handlers, or other persons on site. The SQG must also provide in a conspicuous
place an indication of the hazards of the contents. Examples include, but are
not limited to, the applicable hazardous waste characteristics (i.e.,
ignitable, corrosive, reactive, or toxic); hazard communication consistent with
subpart E (Labeling) and subpart F (Placarding) of 49 CFR
172, incorporated by
reference in 35 Ill. Adm. Code
720.111; a hazard statement or pictogram
consistent with
29 CFR
1910.1200 (Hazard Communication),
incorporated by reference in 35 Ill. Adm. Code
720.111; or a chemical hazard
label consistent with NFPA 704, incorporated by reference in 35 Ill. Adm. Code
720.111. The SQG must also maintain both of the following:
A) The professional engineer certification
that the building complies with the design standards specified in 35 Ill. Adm.
Code
725.1101.
This certification must be in the generator's files prior to operation of the
unit; and
B) The following records,
by use of inventory logs, monitoring equipment, or any other effective means:
i) A written description of procedures to
ensure that each waste volume remains in the unit for no more than 90 days, a
written description of the waste generation and management practices for the
facility showing that the generator is consistent with maintaining the 90 day
limit, and documentation that the SQG complies with the procedures;
or
ii) Documentation that the SQG
empties the unit at least once every 90 days.
iii) The SQG must maintain inventory logs or
records with the above information on site and readily available for
inspection.
6) Labeling and Marking of Containers and
Tanks
A) Containers. An SQG must mark or
label its containers with the following:
i)
The words "Hazardous Waste";
ii) An
indication of the hazards of the contents. Examples include, but are not
limited to, the applicable hazardous waste characteristics (i.e., ignitable,
corrosive, reactive, or toxic); hazard communication consistent with subpart E
(Labeling) and subpart F (Placarding) of 49 CFR
172, incorporated by reference
in 35 Ill. Adm. Code
720.111; a hazard statement or pictogram consistent with
29 CFR
1910.1200 (Hazard Communication),
incorporated by reference in 35 Ill. Adm. Code
720.111; or a chemical hazard
label consistent with NFPA 704, incorporated by reference in 35 Ill. Adm. Code
720.111; and
iii) The date upon
which each period of accumulation begins clearly visible for inspection on each
container.
B) Tanks. An
SQG accumulating hazardous waste in tanks must do the following:
i) Mark or label its tanks with the words
"Hazardous Waste";
ii) Mark or
label its tanks with an indication of the hazards of the contents. Examples
include, but are not limited to, the applicable hazardous waste characteristics
(i.e., ignitable, corrosive, reactive, or toxic); hazard communication
consistent with subpart E (Labeling) and subpart F (Placarding) of 49 CFR
172,
incorporated by reference in 35 Ill. Adm. Code
720.111; a hazard statement or
pictogram consistent with
29 CFR
1910.1200 (Hazard Communication),
incorporated by reference in 35 Ill. Adm. Code
720.111; or a chemical hazard
label consistent with NFPA 704, incorporated by reference in 35 Ill. Adm. Code
720.111;
iii) Use inventory logs,
monitoring equipment, or other records to demonstrate that hazardous waste has
been emptied within 180 days of first entering the tank if using a batch
process or, in the case of a tank with a continuous flow process, demonstrate
that estimated volumes of hazardous waste entering the tank daily exit the tank
within 180 days of first entering; and
iv) Keep inventory logs or records with the
above information on site and readily available for inspection.
7) Land Disposal
Restrictions. An SQG must comply with all the applicable requirements under 35
Ill. Adm. Code
728.
8) Preparedness
and Prevention
A) Maintenance and Operation
of Facility. An SQG must maintain and operate its facility to minimize the
possibility of a fire, explosion, or any unplanned sudden or non-sudden release
of hazardous waste or hazardous waste constituents to air, soil, or surface
water that could threaten human health or the environment.
B) Required Equipment. An SQG must equip all
areas where hazardous waste is either generated or accumulated with the items
in subsections (b)(8)(B)(i) through (b)(8)(B)(iv) (unless none of the hazards
posed by waste handled at the facility could require a particular kind of
equipment specified below or the actual waste generation or accumulation area
does not lend itself for safety reasons to have a particular kind of equipment
specified below). An SQG may determine the most appropriate places to locate
equipment necessary to prepare for and respond to emergencies.
i) An internal communications or alarm system
capable of providing immediate emergency instruction (voice or signal) to
facility personnel;
ii) A device,
such as a telephone (immediately available at the scene of operations) or a
hand-held two-way radio, capable of summoning emergency assistance from local
police departments, fire departments, or State or local emergency response
teams;
iii) Portable fire
extinguishers, fire control equipment (including special extinguishing
equipment, such as that using foam, inert gas, or dry chemicals), spill control
equipment, and decontamination equipment; and
iv) Water at adequate volume and pressure to
supply water hose streams, foam producing equipment, automatic sprinklers, or
water spray systems.
C)
Testing and Maintenance of Equipment. The SQG must test and maintain all
communications or alarm systems, fire protection equipment, spill control
equipment, and decontamination equipment, if required, as necessary to assure
its proper operation in time of emergency.
D) Access to Communications or Alarm System
i) Whenever the SQG pours, mixes, spreads, or
otherwise handles hazardous waste, all personnel involved in the operation must
have immediate access (i.e., direct or unimpeded access) to an internal alarm
or emergency communication device, either directly or through visual or voice
contact with another employee, unless such a device is not required under
subsection (a)(8)(B).
ii) When
there is just one employee on the premises while the facility is operating, the
employee must have immediate access (i.e., direct or unimpeded access) to a
device, such as a telephone (immediately available at the scene of operation)
or a hand-held two-way radio, that is capable of summoning external emergency
assistance, unless such a device is not required under subsection
(a)(8)(B).
E) Required
Aisle Space. The SQG must maintain aisle space that allows the unobstructed
movement of personnel, fire protection equipment, spill control equipment, and
decontamination equipment to any area of facility operation in an emergency,
unless aisle space is not needed for any of these purposes.
F) Arrangements with Local Authorities
i) The SQG must attempt to make arrangements
with the local police department, fire department, other emergency response
teams, emergency response contractors, equipment suppliers, and local
hospitals, taking into account the types and quantities of hazardous wastes
handled at the facility. Arrangements may be made with the Local Emergency
Planning Committee, if this is the appropriate organization with which to make
arrangements. An SQG attempting to make arrangements with its local fire
department must determine the potential need for the services of the local
police department, other emergency response teams, emergency response
contractors, equipment suppliers, and local hospitals. As part of this
coordination, the SQG must attempt to make arrangements, as necessary, to
familiarize the above organizations with the layout of the facility, the
properties of hazardous waste handled at the facility and associated hazards,
places where facility personnel would normally be working, entrances to roads
inside the facility, and possible evacuation routes, as well as the types of
injuries or illnesses that could result from fires, explosions, or releases at
the facility. If more than one police or fire department might respond to an
emergency, the SQG must attempt to make arrangements designating primary
emergency authority to a specific fire or police department and with any others
to provide support to the primary emergency authority.
BOARD NOTE: The State Emergency Response Commission (SERC)
maintains an on-line listing of Local Emergency Planning Committees in Illinois
by jurisdiction:
www.illinois.gov/iema/Preparedness/SERC/Documents/LEPC_ReleaseReportingContactList.pdf.
ii) An SQG must maintain records
documenting the arrangements with the local fire department as well as any
other organization necessary to respond to an emergency. This documentation
must include documentation in the operating record that either confirms these
arrangements actively exist or, in cases where no arrangements exist,
confirming that the SQG attempted to make these arrangements.
iii) A facility possessing 24-hour response
capabilities may seek a waiver from the authority having jurisdiction over the
fire code within Illinois or the facility's locality, as far as needing to make
arrangements with the local fire department as well as any other organization
necessary to respond to an emergency, provided that the SQG documents the
waiver in the operating record.
9) Emergency Procedures. The SQG must comply
with the following conditions for those areas of the generator facility where
hazardous waste is generated and accumulated:
A) At all times, at least one employee must
be either on the premises or on call (i.e., available to respond to an
emergency by reaching the facility within a short period of time) with the
responsibility for coordinating all emergency response measures specified in
subsection (b)(9)(D). This employee is the emergency coordinator.
B) The SQG must post the following
information next to telephones or in areas directly involved in the generation
and accumulation of hazardous waste:
i) The
name and emergency telephone number of the emergency coordinator;
ii) The location of fire extinguishers and
spill control material, and, if present, fire alarm; and
iii) The telephone number of the fire
department, unless the facility has a direct alarm.
C) The SQG must ensure that all employees are
thoroughly familiar with proper waste handling and emergency procedures that
are relevant to their responsibilities during normal facility operations and
emergencies;
D) The emergency
coordinator or his or her designee must respond to any emergencies that arise.
The required responses are the following:
i)
In the event of a fire, the emergency coordinator must call the fire department
or attempt to extinguish the fire using a fire extinguisher;
ii) When a spill occurs, the SQG must contain
the flow of hazardous waste to the extent possible and, as soon as is
practicable, clean up the hazardous waste and any contaminated materials or
soil. The SQG can either itself conduct this containment and cleanup or have a
contractor perform the work on its behalf;
iii) When a fire, explosion, or other release
occurs that could threaten human health outside the facility, or when the SQG
has knowledge that a spill has reached surface water, the SQG must immediately
notify the National Response Center (using the 24-hour toll free number,
800-424-8802). The report must include the name, address, and USEPA
identification number of the SQG; the date, time, and type of incident
(e.g., spill or fire); the quantity and type of hazardous
waste involved in the incident; the extent of any injuries; and the estimated
quantity and disposition of any recovered materials.
d) Accumulation Time Limit Extension. An SQG
that accumulates hazardous waste for more than 180 days (or for more than 270
days if the SQG must transport its waste or offer its waste for transportation
over a distance of 200 miles or more for off-site treatment, storage, or
disposal) is subject to the requirements of 35 Ill. Adm. Code
702,
703,
724,
725,
727, and 728, unless the Agency has granted the SQG an extension to the
180-day (or 270-day if applicable) period. The Agency may grant an extension if
hazardous wastes must remain on site for longer than 180 days (or 270 days if
applicable) due to unforeseen, temporary, and uncontrollable circumstances. The
Agency may grant an extension of up to 30 days on a case-by-case basis.
BOARD NOTE: The Agency may grant a provisional variance that
extends the permissible accumulation period under sections 35(b) and 36(c) of
the Act. This subsection provides the basis for granting and maximum duration
of an extension.