Ill. Admin. Code tit. 35, § 811.305 - Foundation Construction
a) If the
in situ material provides insufficient strength to meet the requirements of
Section
811.304,
then the insufficient material shall be removed and replaced with clean
material sufficient to meet the requirements of Section 811.304.
b) All trees, stumps, roots, boulders and
debris shall be removed.
c) All
material shall be compacted to achieve the strength and density properties
necessary to demonstrate compliance with this Part in conformance with a
construction quality assurance plan pursuant to Subpart E.
d) Placement of frozen soil or soil into
frozen ground is prohibited.
e) The
foundation shall be constructed and graded to provide a smooth, workable
surface on which to construct the liner.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.