Iowa Admin. Code r. 567-63.16 - Sampling procedures for monitoring wells

The following steps shall be taken prior to monitoring well sampling.

(1) Measure depth from top of well head casing to water table.
(2) Calculate quantity of water to be flushed from well using the formula:

Gallons to be pumped = 0.221 d(squared)h, where:

d = well diameter in inches

h = depth in feet of standing water in well prior to pumping

(3) Pump well.
(4) Measure depth from well head casing to water table after pumping.
(5) Wait for well to recharge to or near static water level prior to sampling.

Notes

Iowa Admin. Code r. 567-63.16
Adopted by IAB February 9, 2022/Volume XLIV, Number 16, effective 3/16/2022

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.