06-096 C.M.R. ch. 130, § 3 - Cold Cleaning Machines
This section applies to all cold cleaning machines that process metal parts. (See 1B Exemptions.) The provisions of this Section shall not apply if the owner and operator of the cold cleaning machine demonstrates and the Department approves in writing that compliance with the Section will result in unsafe operating conditions.
A. Immersion cold cleaning machines shall
have a freeboard ratio of 0.75 or greater unless the machines are equipped with
covers that are kept closed except when parts are being placed into or being
removed from the machine.
B.
Immersion cold cleaning machines and remote reservoir cold cleaning machines
shall:
(1) Have a permanent, conspicuous label
summarizing the operating requirements in Subsection 3 below.
(2) Be equipped with a cover that shall be
closed at all times except during cleaning of parts or the addition or removal
of solvent. For remote reservoir cold cleaning machines which drain directly
into the solvent storage reservoir, a perforated drain with a diameter of not
more than six inches shall constitute an acceptable cover.
(3) Cold cleaning machines shall be operated
in accordance with the following procedures:
(a) Waste solvent shall be collected and
stored in closed containers. The closed containers may contain a device that
allows pressure relief, but does not allow liquid solvent to drain from the
container;
(b) Cleaned parts shall
be drained at least 15 seconds or until dripping ceases, whichever is longer.
Parts having cavities or blind holes shall be tipped or rotated while the part
is draining. During the draining, tipping or rotating, the parts shall be
positioned so that solvent drains directly back to the cold cleaning
machine;
(c) Flushing of parts
using a flexible hose or other flushing device shall be performed only within
the freeboard area of the cold cleaning machine. The solvent spray shall be a
solid fluid stream, not an atomized or shower spray at a pressure that does not
exceed 10 pounds per square inch gauge (psig);
(d) The owner or operator shall ensure that,
when the cover is open, the cold cleaning machine is not exposed to drafts
greater than 40 meters per minute (132 feet per minute), as measured between 1
and 2 meters (3.3 and 6.6 feet) upwind and at the same elevation as the tank
lip;
(e) Sponges, fabric, wood,
leather, paper products and other absorbent materials shall not be cleaned in
the cold cleaning machine;
(f) When
a pump-agitated solvent bath is used, the agitator shall be operated to produce
a rolling motion of the solvent with no observable splashing of the solvent
against the tank walls or the parts being cleaned. Air agitated solvent baths
may not be used;
(g) Spills during
solvent transfer and use of the cold cleaning machine shall be cleaned up
immediately, and the wipe rags or other sorbent material shall be immediately
stored in covered containers for disposal or recycling;
(h) Work area fans shall be located and
positioned so that they do not blow across the opening of the degreaser unit;
and
(i) The owner or operator shall
ensure that the solvent level does not exceed the fill line.
C. On and after May 1,
2005, a person who sells or offers for sale any solvent containing volatile
organic compounds for use in a cold cleaning machine shall provide to the
purchaser the following written information:
(1) The name and address of the solvent
supplier;
(2) The type of solvent
including the product or vendor identification number;
(3) The vapor pressure of the solvent
measured in mm Hg at 20o C
(68o F); and
(4) Percent VOC content by weight.
D. A person who operates a cold
cleaning machine shall maintain for not less than two years and shall provide
to the Maine Department of Environmental Protection or EPA, on request, the
information specified in Subsection 3C. An invoice, bill of sale, certificate
that corresponds to a number of sales, Material Safety Data Sheet (MSDS), or
other appropriate documentation acceptable to the Department and EPA may be
used to comply with this Section.
E. On, or after, May 1, 2005, each cold
cleaning machine must use a solvent with a vapor pressure of 1.00 mm Hg, or
less, at 20o C (68o F).
This paragraph does not apply to cold cleaning machines:
(1) Used in special and extreme solvent metal
cleaning;
(2) For which the owner
or operator has received Department approval of a demonstration that compliance
with the requirement of a solvent with a vapor pressure of 1.0 mm Hg, or less,
at 20o C will result in unsafe operating conditions;
or
(3) That are located in a
permanent total enclosure having control equipment that is designed and
operated with an overall VOC removal efficiency of 90 percent or
greater.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.