06-096 C.M.R. ch. 162, § 6 - Cleaning solvent standards
A. The volatile
organic compound content of cleaning solvents employed for routine application
equipment cleaning shall contain a maximum of 5.0 per cent VOC by weight, or
have a composite vapor pressure of no more than 0.50 mm Hg at sixty-eight
degrees Fahrenheit, as determined by the cleaning solvent manufacturer's
Material Safety Data Sheet (MSDS) or other appropriate documentation acceptable
to the Department and EPA.
B. Only
non-volatile organic compound solvents shall be used to remove cured resin and
gel coat from application equipment.