06-096 C.M.R. ch. 170, § 3 - Definitions
As used in this Chapter, unless otherwise indicated, the following terms have the listed meanings.
A.
Affected product. "Affected
product" means gasoline, aviation gasoline, ethanol, and crude oil. For the
purposes of this Chapter, propane or compressed gases, residual fuel oils, and
distillate fuel oils are not considered affected products.
B.
Degassing or Degassing event.
"Degassing" or "Degassing event" means the process of removing organic vapors
from a petroleum storage tank, transport vessel, or marine vessel cargo tank
during or in preparation for human entry, cleaning, and/or maintenance
activity.
C.
Liquid
leak. "Liquid leak" means the visible dripping of an affected
product.
D.
Marine
vessel. "Marine vessel" means any watercraft, including oil tankers and
barges, used as a means of transportation to carry affected products over
water.
E.
Marine vessel cargo
tank. "Marine vessel cargo tank" means a liquid-tight shell designed to
contain the cargo.
F.
Petroleum storage facility."Petroleum storage facility" means a
storage facility that receives affected products from refineries or other
storage locations primarily by pipeline or marine vessel and delivers those
products to refineries, other storage facilities, bulk plants, or to commercial
or retail accounts by pipeline, marine vessel, or transport vessel. For the
purposes of this Chapter, a petroleum storage facility does not include
aboveground petroleum storage tanks located at industrial manufacturing or
electrical generating facilities.
G.
Petroleum storage tank.
"Petroleum storage tank" means an aboveground container which is used for the
storage of affected products.
H.
Transport vessel. "Transport vessel" means any land-based mode of
transportation (truck or rail) equipped with a storage tank that is used to
transport affected products. Vessels used exclusively for maintenance and spill
response are not considered to be transport vessels.
I.
Vapor control system. "Vapor
control system" means the equipment and systems used to reduce volatile organic
compound emissions from a degassing event conducted on petroleum storage tanks,
marine vessel cargo tanks, and transport vessels.
J.
Vapor leak. "Vapor leak"
means a failure of containment that results in the presence of gaseous volatile
organic compounds at or above 500 parts per million by volume (ppmv) measured
as methane above background on a portable hydrocarbon analyzer, in accordance
with 40 C.F.R. Part 60, Appendix A, Method 21 as amended 10/17/2000.
K.
Vapor tight condition. "Vapor
tight condition" means the condition that exists when the reading on a portable
hydrocarbon analyzer is less than 500 parts per million by volume (ppmv),
measured as methane above background, in accordance with 40 C.F.R. Part 60,
Appendix A, Method 21 as amended 10/17/2000.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.