Md. Code Regs. 13B.07.05.02 - Capital Guidelines

Space allocation guidelines for college campuses are as follows:

Room Use Category Space Factor by Size of FTDE
HEGIS Code Space Base 3000 & Under 3001 & Up
100 Classroom Facilities WSCH1 1.50 1.11
110 Classroom
200 Laboratory Facilities WSCH2 7.00 5.83
210 Class Laboratory
220 Open Laboratory FTDE 4.20 4.20
300 Office FTEF3 166.00 166.00
FT Staff
Student Offices4
320 Testing & Tutoring Centers FTDE5 Core of 1,500 NASF and 0.5 NASF/FTDE in excess of 1,500 FTDE.
400 Library
410 Study/Seating FTDE 6.25 6.25
420 Stack BVE6 .10- .10+
400-455 Processing Percent of 420 with minimum of 1,200 NASF7 .40 .40
500 Special Use
520 Physical Education-Pool, Gym, and Fitness/Wellness Center FTDE8 Core of 28,000 NASF (consisting of 14,000 for a gym, 8,000 for a pool, and 6,000 for a fitness center) and 10 NASF/FTDE in excess of 1,500 FTDE and 6,000 NASF of service space (consisting of 3,500 for lockers and 2,500 for storage).
530 Audiovisual, Radio, TV FTDE Core of 1,600 NASF and 0.8 NASF/FTDE in excess of 1,500 FTDE up to 3,000 FTDE and 2 NASF/FTDE in excess of 3,000 FTDE.
580 Greenhouse Campus Core of 1,000 NASF
600 General Use
610 Assembly FTDE Core of 12,000 NASF and 2 NASF/FTDE in excess of 1,500 FTDE.
620 Exhibition FTDE Core of 1,500 NASF and 0.5 NASF/FTDE in excess of 1,500 FTDE.
630 Food Facilities PHC9 10.2 8.4
650 Lounge Facilities PHC10 3.0 3.0
660 Merchandising FTDE Core of 1,600 NASF and 0.5 NASF/FTDE in excess of 1,500 FTDE.
680 Meeting Space FTDE Core of 6,000 NASF Core of 8,000 NASF
700 Support
710 Data Processing, Telecomm FTDE11 Core of 2,500 NASF for the first 4,000 FTDE and 0.75 NASF/FTDE beyond 4,000 FTDE.
720-745 Shops, Storage, Vehicle Storage, and Repair Total Campus Allowance minus this category12 0.04 0.04
750 Central Service FTDE Core of 4,000 NASF for the first 4,000 FTDE and 1 NASF/FTDE beyond 4,000 FTDE.
760 Hazardous Materials Total Storage 2% of existing inventory in Room Use Categories 720-745.
800 Health Care FTDE Core of 500 NASF and 0.2 NASF/FTDE in excess of 1,500 FTDE.

1WSCH-Lecture. Weekly student contact hours for on-campus day students in credit courses and eligible noncredit courses where instruction is lecture.

2WSHC-Lab. Weekly student contact hours for on-campus day students in credit courses and eligible noncredit courses where instruction is lab.

3FTEF-Full-time equivalent faculty, including librarians, plus 25% of all part-time faculty.

41,120 square feet maximum for student offices.

5FTDE-Full-time day equivalent is total credit hours taught on campus between 8 a.m. and 5 p.m. divided by 15 credit hours.

6BVE-Bound volume equivalent which is 20,000 BVE for the first 1,000 FTE and 1,000 BVE for every 100 FTE above 1,000.

7A minimum allowance is needed for cataloging, binding, and maintenance regardless of collection size.

8Minimum size of gym is 14,000 NASF for activity space, 8,000 NASF for pool, 6,000 NASF for fitness space, 3,500 NASF for lockers, and 2,500 NASF for storage.

9PHC-Planning headcount is 50% of FTDE for on-campus credit and eligible noncredit courses plus FTEF and FT Staff and includes space for seating, preparation, and storage.

10Allowance includes quiet, study, and building lounges.

11FTDE for on-campus credit courses and eligible noncredit courses.

12Allowance related to required service space on campus total square footage.

13 Computed need in any larger institutional size category may not be less than the maximum amount for any smaller institutional size category.

Notes

Md. Code Regs. 13B.07.05.02
Regulations .02 and new Regulation .02 adopted effective April 15, 2002 (29:7 Md. R. 621); amended effective 43:25 Md. R. 1385, eff. 12/19/2016

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.