Mich. Admin. Code R. 400.10519 - Facility construction

Rule 519.

(1) A new, substantially remodeled, or converted large or secure facility shall be 1 of the following types of construction as specified in the national fire protection association pamphlet no. 220, entitled "Standard on Types of Building Construction, 1979":
(a) Type I 443 or 332 or type II 222.
(b) Type II 111, type III 211, type IV 2HH, or type V 111 up to 2 stories. A basement and second story for these types of construction require complete sprinkler protection.
(c) Type II 000, type III 200, or type V 000 up to 2 stories, with all stories completely covered by sprinkler protection.
(2) New, converted, and substantially remodeled small facilities shall be at least frame construction and shall be fire-stopped with not less than 2-inch nominal lumber at all wall and floor junctures and all wall and ceiling junctures.
(3) Existing construction which was approved before these rules take effect and which meets the construction requirements of the fire safety guidelines these rules supersede shall continue to be approved until the facility is substantially remodeled or converted. When an existing facility is substantially remodeled or added to, only the portion of the facility being substantially remodeled or added need be in compliance with the provisions of subrule (1) or (2) of this rule, as appropriate.

Notes

Mich. Admin. Code R. 400.10519
1992 AACS