Mich. Admin. Code R. 408.10671 - Fire escape stairs
Rule 671.
(1)
Fire escape stairs may be used as a required exit only in existing buildings.
Fire escape stairs shall not constitute more than 50% of the required exit
capacity. Fire escape stairs shall not constitute any part of the required
exits for a new building.
(2) Fire
escape stair dimensions shall be in accordance with table 4.
TABLE 4 | |
Minimum Width | 22 inches clear between rails |
Minimum horizontal dimension of a landing or platform | 22 inches |
Maximum rise | 9 inches |
Minimum tread, exclusive of nosing | 9 inches |
Spiral winders | Not permitted |
Maximum height between landings | 12 feet |
(3) Fire escape stairs shall have walls or
approved guards, and handrails on both sides.