Mich. Admin. Code R. 408.10671 - Fire escape stairs

Rule 671.

(1) Fire escape stairs may be used as a required exit only in existing buildings. Fire escape stairs shall not constitute more than 50% of the required exit capacity. Fire escape stairs shall not constitute any part of the required exits for a new building.
(2) Fire escape stair dimensions shall be in accordance with table 4.

TABLE 4
Minimum Width 22 inches clear between rails
Minimum horizontal dimension of a landing or platform 22 inches
Maximum rise 9 inches
Minimum tread, exclusive of nosing 9 inches
Spiral winders Not permitted
Maximum height between landings 12 feet
(3) Fire escape stairs shall have walls or approved guards, and handrails on both sides.