Mich. Admin. Code R. 408.14433 - Gangways and aisles
Rule 4433.
(1) A
gangway or aisle in which molten metal is being transported must be clear of
obstructions and water.
(2) A
gangway must be not less than 4 feet wide or must be 3 feet wider than the
widest load for which it is used.
(3) A work station must be not less than 2
feet from aisles and gangways, except when protected by a guardrail system, in
compliance with General Industry Safety and Health Standard Part 2.
"Walking-Working Surfaces," being
R
408.10201 to
R
408.10241 of the Michigan Administrative
Code.
(4) Access to and from a work
station must be free of obstructions.