Mich. Admin. Code R. 408.15751 - Wireline service generally

Rule 5751.

(1) Wireline wipers shall be secured to prevent displacement.
(2) Oil savers shall be adjusted only by remote control while the wireline is in motion.
(3) Except for an employee of the wireline service company, an employee shall not be permitted closer than 6 feet to a moving wireline when working between the wireline unit and the well.
(4) The wireline valve, sometimes called a wireline blowout preventer, shall be visually inspected during opening and closing each time it is installed on a well. It shall be pressure tested monthly in full closed position to the rated working pressure of the valve.

Notes

Mich. Admin. Code R. 408.15751
1979 AC

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.