Mich. Admin. Code R. 408.17225 - Flammables, painting and coating

Rule 7225.

(1) A Class I flammable solvent stored inside a building shall be in an approved safety can with an automatic closing cap and flame arrestor or original unopened container having a capacity of not more than 5 gallons. Quantities in excess of 5 gallons shall be stored as prescribed by flammable liquid regulations of the fire marshal promulgated under 1941 PA 207.
(2) When pouring a flammable solvent from 1 container to another, continuous contact between the containers shall be maintained or a bonding or grounding strap shall connect the containers.
(3) A Class I flammable solvent shall not be used for cleaning tools, parts, floors, or booths.
(4) When a flammable liquid is removed from a vehicle tank, an approved pumping device equipped with a ground strap shall be used.

Notes

Mich. Admin. Code R. 408.17225
1979 AC; 2013 AACS

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.