Mich. Admin. Code R. 408.31137 - Labels
Rule 1137.
(1)
Each premanufactured unit or building component or group of components, which
is certified pursuant to the act and these rules, shall have permanently
attached thereto an approved label which cannot be removed therefrom without
destroying the label. The approved label or labels shall be placed in the
following areas:
(a) Models, residential
modular units - 2 or more labels - 1 placed in cabinet under kitchen sink, 1
placed in front closet, additional units placed - 1 in each section, readily
accessible by the building officials, and so shown on the approved building
system.
(b) Residential structural
building components, panelized units - 1 label placed on electrical panel or in
cabinet under kitchen sink or in a place readily accessible by the building
official and so shown on the approved building system.
(c) All other - 1 or more labels placed
readily accessible by the building official and so shown on the approved
building system.
(2) An
approved label shall bear the following information:
(a) "This label certifies that this unit (or
building component) has been manufactured in accordance with a building system
and compliance assurance program approved by the construction code commission
and inspected by (name of inspection agency) under the auspices and approval of
the state of Michigan."
(b) Label
serial number.
(c) Building system
approval number.
(d) Manufacturer's
serial number.
(e) The words "See
data plate located on _____ ."
(f)
The name of the agency issuing the label.
(3) At the discretion of the bureau, labels
and data plates may be limited in size and content for components whose shape
or size does not permit the full information to be placed thereon.
(4) The approved label shall be issued by the
commission or its agents in accordance with the following:
(a) The commission and the bureau shall
specify the manner in which the labels are handled.
(b) Labels shall be numbered
serially.
(c) A manufacturer's
compliance assurance program, submitted in accordance with
R 408.31161, shall include
requirements for issuance, possession, attachment and accounting of all labels
to assure that labels are attached only to units or building components
manufactured pursuant to an approved building system and inspected pursuant to
an approved compliance assurance program.
(5) Permanent records shall be kept of the
handling of all labels, indicating at least how many labels have been applied
to units, building components, or groups of components, which labels have been
applied to which units or building components, and the disposition of any
damaged or rejected labels, and the location and custody of all unused labels.
All inspection agencies shall be required to submit twice a week to the bureau,
on forms furnished by the bureau, reports showing the above required
information. Each manufacturer shall be required to submit to the bureau, a
monthly report showing the number of units, building components or groups of
components shipped, the label numbers applied thereto, the manufacturer's
serial number, the date of manufacture, and the location to which the unit,
building component, or group of components was shipped.
(6) The commission or an inspection agency
shall attach labels to units or building components manufactured in accordance
with an approved compliance assurance program.