Mich. Admin. Code R. 408.40133 - Illumination
Rule 133.
(1)
The employer shall provide a minimum illumination intensity of 10 footcandles
on a jobsite where construction work is being performed.
(2) The employer shall provide a minimum
illumination intensity of 5 footcandles to areas on a jobsite where work is not
being immediately performed but where workers may pass through.
(3) The employer shall provide a minimum
illumination intensity of 50 footcandles for first aid stations and
infirmaries.
(4) For areas or
operations not covered by subrules (1) to (3) of this rule, refer to ANSI A11.1
"Industrial lighting," 1965 edition, as adopted in
R
408.40105.