Mich. Admin. Code R. 408.7062 - Runway entrance

Rule 62. Section 2.1.1.2 of the ASME A18.1 code is amended to read as follows: 2.1.1.2 The runway entrance must be guarded at the upper landing by a door of unperforated construction not wider than the platform plus 1 inch, or 25.4 millimeters. The door must be self-closing or power operated and guard the entire opening to a height equal to or higher than the height of the platform enclosure. The openings created in the runway by these doors must provide a minimum vertical clearance of 6 feet 8 inches. The doors must guard the entire area of the openings except for space necessary for operation. Space necessary for operation must reject a ball 12 mm, or 0.5 inches, in diameter. The lift side of the landing doors and sill must present a smooth surface located not closer than 10 mm, or 0.375 inches, or more than 20 mm, or 0.75 inches, from the platform floor.

Notes

Mich. Admin. Code R. 408.7062
2003 AACS; 2010 AACS; 2023 MR 6, Eff. 3/29/2023

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.