Nev. Admin. Code § 554.450 - Air circulation systems in railway cars or vans
1.
Each loaded railway car or trucking van must be prepared so that air can be
withdrawn from beneath the grain and returned to the space above the load. This
must be provided by a system of probes inserted in the grain and connected by
flexible tubing to a portable blower outside of the car which returns the air
to the space above the load.
2. The
probe system must consist of ten probes 6 feet long inserted equidistant in a
line down the center of the car so that the perforated tips are near the
floor.
3. The probes must be
connected by flexible tubing proportioned so that there is equal suction on
each probe.
4. One doorway must be
sealed with gastight laminated paper. The ducts must lead through this seal to
the portable blower.
5. The blower
must have a capacity of at least 625 cubic feet per minute against a 5-inch
static pressure and must be of a design that can be made gastight. The gas may
be introduced as a spray or through a volatilizer into the exhaust duct at any
point between the blower and the car or van, or may be introduced directly into
the space above the load.