N.J. Admin. Code § 7:9A-4.4 - Slope

(a) No disposal field or seepage pit shall be located in an area where the slope of the existing ground surface is greater than 25 percent.
(b) Where the slope is greater than 10 percent, no disposal field or seepage pit shall be placed less than 50 feet upslope of any bedrock outcrop where signs of ground water seepage can be detected.
(c) Modification of slopes by re-grading shall meet the requirements of 7:9A-10.3(b).

Notes

N.J. Admin. Code § 7:9A-4.4
Amended by R.2012 d.066, effective 4/2/2012.
See: 43 N.J.R. 478(a), 44 N.J.R. 1047(a).
In (a), substituted "No" for "The", deleted "not" following "shall" and inserted "of the existing ground surface".

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.