N.Y. Comp. Codes R. & Regs. Tit. 16 § 255.613 - Continuing surveillance
(a) Each
operator shall have a procedure for continuing surveillance of its facilities
to determine and take appropriate action concerning changes in class location,
failures, leakage history, corrosion, substantial changes in cathodic
protection requirements, and other unusual operating and maintenance
conditions.
(b) If a segment of
pipeline is determined to be in unsatisfactory condition but no immediate
hazard exists, the operator shall initiate a program to recondition or phase
out the segment involved, or, if the segment cannot be reconditioned or phased
out, reduce the maximum allowable operating pressure in accordance with section
255.619(a) and
(b) of this Part.