N.Y. Comp. Codes R. & Regs. Tit. 19 § 1264.4 - Identification of truss type construction
(a) Truss type
construction shall be identified by a sign or signs in accordance with the
provisions of this Part.
(b) Signs
shall be affixed where a building or a portion thereof is classified as Group
A, B, E, F, H, I, M or S occupancy, and in hotels and motels classified as
Group R-1 or R-2 occupancy, in accordance with the provisions for the
classification of buildings set forth in chapter 3 of the 2020 Building Code of
New York State (said publication being incorporated by reference in Part 1221
of this Title).
(c) Signs shall be
provided in newly constructed buildings that utilize truss type construction
and in existing buildings where an addition that extends or increase the floor
area of the building utilizes truss type construction. Signs shall be affixed
prior to the issuance of a certificate of occupancy or a certificate of
compliance.
(d) Signs identifying
the existence of truss construction shall consist of a circle six inches (152.4
mm) in diameter, with a stroke width of 1/2 inch (12.7 mm). The sign background
shall be reflective white in color. The circle and contents shall be reflective
red in color, conforming to Pantone matching system (PMS) #187. Where a sign is
directly applied to a door or sidelight, it may be a permanent non-fading
sticker or decal. Signs not directly applied to doors or sidelights shall be of
sturdy, non-fading, weather-resistant material.
(e) Signs identifying the existence of truss
construction shall contain the roman alphanumeric designation of the
construction type of the building, in accordance with the provisions for the
classification of types of construction set forth in section 602 of the 2020
Building Code of New York State (said publication being incorporated by
reference in Part 1221 of this Title), and an alphabetic designation for the
structural components that are of truss construction, as follows:
"F" shall mean floor framing, including girders and beams
"R" shall mean roof framing
"FR" shall mean floor and roof framing
The construction type designation shall be placed at the 12 o'clock position over the structural component designation, which shall be placed at the six o'clock position.
(f) Signs identifying the existence of truss
construction shall be affixed in the locations specified in Table I-1264 of
this section.
TABLE I-1264
TRUSS IDENTIFICATION SIGN LOCATIONS
Sign location | Sign placement |
Exterior building entrance doors, exterior exit discharge doors, and exterior roof access doors to a stairway | Attached to the door, or attached to a sidelight or the face of the building, not more than 12 inches (305 mm) horizontally from the latch side of the door jamb, and not less than 42 inches (1,067 mm) nor more than 60 inches (1,524 mm) above the adjoining walking surface |
Multiple contiguous exterior building entrance or exit discharge doors | Attached at each end of the row of doors and at a maximum horizontal distance of 12 feet (3.65 m) between signs, and not less than 42 inches (1,067 mm) nor more than 60 inches (1,524 mm) above the adjoining walking surface |
Fire department hose connections | Attached to the face of the building, not more than 12 inches (305 mm) horizontally from the center line of the fire department hose connection, and not less than 42 inches (1,067 mm) nor more than 60 inches (1,524 mm) above the adjoining walking surface |
Notes