Ohio Admin. Code 3701:1-52-23 - Inspection and maintenance
(A) The licensee shall perform inspection and
maintenance checks that include, as a minimum, each of the following at the
frequency specified in the license or license application:
(1) Operability of each aspect of the access
control system required by rule
3701:1-52-08 of the
Administrative Code.
(2)
Functioning of the source position indicator required by paragraph (B) of rule
3701:1-52-12 of the
Administrative Code.
(3)
Operability of the radiation monitor for radioactive contamination in pool
water required by paragraph (B) of rule
3701:1-52-22 of the
Administrative Code using a radiation check source, if applicable.
(4) Operability of the over-pool radiation
monitor at underwater irradiators as required by paragraph (B) of rule
3701:1-52-11 of the
Administrative Code.
(5)
Operability of the product exit monitor required by paragraph (A) of rule
3701:1-52-11 of the
Administrative Code.
(6)
Operability of the emergency source return control required by paragraph (C) of
rule 3701:1-52-12 of the
Administrative Code.
(7) A visual
inspection of the leak-tightness of systems through which pool water
circulates.
(8) Without turning
extinguishers on, operability of the heat and smoke detectors and extinguisher
system required by rule
3701:1-52-10 of the
Administrative Code.
(9)
Operability of the means of pool water replenishment required by paragraph (C)
of rule
3701:1-52-13 of the
Administrative Code.
(10)
Operability of the indicators of high and low pool water levels required by
paragraph (D) of rule
3701:1-52-13 of the
Administrative Code.
(11)
Operability of the intrusion alarm required by paragraph (I) of rule
3701:1-52-08 of the
Administrative Code, if applicable.
(12) Functioning and wear of the system,
mechanisms, and cables used to raise and lower sources.
(13) Condition of the barrier to prevent
products from hitting the sources or source mechanism as required by rule
3701:1-52-14 of the
Administrative Code.
(14) Amount
of water added to the pool to determine if the pool is leaking.
(15) Electrical wiring on required safety
systems for radiation damage.
(16)
Pool water conductivity measurements and analysis as required by paragraph (B)
of rule
3701:1-52-24 of the
Administrative Code.
(B) Malfunctions and defects found during
inspection and maintenance checks must be repaired without undue delay.
Notes
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002, 10/08/2007
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002, 10/8/07
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.