Ohio Admin. Code 3745-57-05 - Monitoring and inspection
(A) During construction or installation,
liners (except in the case of existing portions of landfills exempt from
paragraph (A) of rule
3745-57-03
of the Administrative Code) and cover systems (e.g., membranes, sheets, or
coatings) must be inspected for uniformity, damage, and imperfections (e.g.,
holes, cracks, thin spots, or foreign materials). Immediately after
construction or installation:
(1) Synthetic
liners and covers must be inspected to ensure tight seams and joints and the
absence of tears, punctures, or blisters; and
(2) Soil-based and admixed liners and covers
must be inspected for imperfections including lenses, cracks, channels, root
holes, or other structural non-uniformities that may cause an increase in the
permeability of the liner or cover.
(B) While a landfill is in operation, it must
be inspected weekly and after storms to detect evidence of any of the
following:
(1) Deterioration, malfunctions,
or improper operation of run-on and run-off control systems; and
(2) Proper functioning of wind dispersal
control systems, where present; and
(3) The presence of leachate in and proper
functioning of leachate collection and removal systems, where present.
Notes
Rule promulgated under: RC Chapter 119.
Rule amplifies: RC 3734.12