Ohio Admin. Code 3745-68-04 - Monitoring and inspection
(A) An owner or operator required to have a
leak detection system under paragraph (A) of rule
3745-68-05
of the Administrative Code must record the amount of liquids removed from each
leak detection system sump at least once each week during the active life and
closure period.
(B) After the final
cover is installed, the amount of liquids removed from each leak detection
system sump must be recorded at least monthly. If the liquid level in the sump
stays below the pump operating level for two consecutive months, the amount of
liquids in the sumps must be recorded at least quarterly. If the liquid level
in the sump stays below the pump operating level for two consecutive quarters,
the amount of liquids in the sumps must be recorded at least semi-annually. If
at any time during the post-closure care period the pump operating level is
exceeded at units on quarterly or semi-annual recording schedules, the owner or
operator must return to monthly recording of amounts of liquids removed from
each sump until the liquid level again stays below the pump operating level for
two consecutive months.
(C) "Pump
operating level" is a liquid level proposed by the owner or operator and
approved by the director based on pump activation level, sump dimensions, and
level that avoids backup into the drainage layer and minimizes head in the
sump. The timing for submittal and approval of the proposed "pump operating
level" will be in accordance with paragraph (A) of rule
3745-68-02 of
the Administrative Code.