Standard Referenced | Title |
A112.1.2-2012 | Air Gaps in Plumbing Systems |
A112.1.3-2000 (R2015) | Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances |
A112.3.1-2007 (2014) | Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground |
ASME Al 12.3.4-2013/ | Macerating Toilet Systems and Related |
CSAB 45.9 -2013 | Components |
A112.4.1-2009 (R2014) | Water Heater Relief Valve Drain Tubes |
Al 12.4.2-2075 | Water Closet Personal Hygiene Devices |
A112.4.3-1999 (R2015) | Plastic Fittings for Connecting Water Closets |
| to the Sanitary Drainage System |
A112.4.14-2004 (R2010) | Manually Operated, Quarter-Turn Shutoff |
| Valves for Use in Plumbing Systems |
A112.6.1M-1997 (R2012) | Floor-affixed Supports for Off-the-floor |
| Plumbing Fixtures for Public Use |
A112.6.2-2000 (R2010) | Framing-affixed Supports for Off-the-floor |
| Water Closets with Concealed Tanks |
A112.6.3-2016 | Floor and Trench Drains |
A112.6.4-2003 (R2012) | Roof, Deck, and Balcony Drains |
A112.6.7-2010 (R2015) | Enameled and Epoxy-coated Cast-iron and |
| PVC Plastic Sanitary Floor Sinks |
A112.6.9-2005 (R2015) | Siphonic Roof Drains |
A112.14.1-2003 (R2012) | Backwater Valves |
A112.14.3-2000 (R2014) | Grease Interceptors |
A112.14.4-2001 (R2012) | Grease Removal Devices |
A112.14.6-2010 (R2015) | FOG (Fats, Oils and Greases) Disposal |
| Systems |
A112.18.1-2012/ | Plumbing Supply Fittings |
CSA B 125.1 -2012 | |
A112.18.2-2015/ | Plumbing Waste Fittings |
CSA B 125.2 -2015 | |
A112.18.3-2002 (R2012) | Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings |
A112.18.6/ | Flexible Water Connectors |
CSA B 125.6 -2009 (R2014) | |
A112.18.7-1999 (R2004) | Deck mounted Bath/Shower Transfer Valves |
| with Integral Backflow Protection |
A112.18.9-2011 | Protectors/Insulators for Exposed Waste and |
| Supplies on Accessible Fixtures |
A112.19.1/-2013 | Enameled Cast Iron and Enameled Steel |
CSA B 45.2 -2013 | Plumbing Fixtures |
A112.19.2-2013/ | Ceramic Plumbing Fixtures |
CSA B 45.1 -13 | |
A112.19.3-2008/ | Stainless Steel Plumbing Fixtures |
CSA B 45.4 -08(R2013) | |
A112.19.5/-2011 | Flush Valves and Spuds for Water-closets, |
CSA B 45.15 -2011 | Urinals, and Tanks |
A112.19.7M-2012/ | Hydromassage Bathtub Systems |
CSA B 45.10 -2012 | |
A112.19.12-2014 | Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and Pivoting Lavatory, Sink and Shampoo Bowl Carrier Systems and Drain Systems |
A112.19.14-2013 | Six-Liter Water Closets Equipped with a Dual Flushing Device |
A112.19.15-2012 | Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors |
A112.19.19-2006 | Vitreous China Nonwater Urinals |
A112.21.3-1985(R2007) | Hydrants for Utility and Maintenance Use |
A112.36.2M-1991(R2012) | Cleanouts |
ASSE 1016/ ASME | Performance Requirements for Individual |
A 112.1016 / | Thermostatic, Pressure Balancing and |
CSA B 125.16 -2011 | Combination Control Valves for Individual Fixture Fittings |
B1.20.1-2013 | Pipe Threads, General Purpose (inch) |
B 16.3 -2011 | Malleable Iron Threaded Fittings Classes 150 and 300 |
B 16.4 -2011 | Gray Iron Threaded Fittings Classes 125 and 250 |
B 16.9 -2012 | Factory-made Wrought Steel Buttwelding Fittings |
B 16.11 -2011 | Forged Fittings, Socket-welding and Threaded |
B 16.12 -2009 (R2014) | Cast-iron Threaded Drainage Fittings |
B 16.15 -2013 | Cast Bronze Threaded Fittings |
B 16.18 -2012 | Cast Copper Alloy Solder Joint Pressure Fittings |
B 16.22 -2013 | Wrought Copper and Copper Alloy Solder Joint Pressure Fittings |
B 16.23 -2011 | Cast Copper Alloy Solder Joint Drainage Fittings DWV |
B 16.26 -2013 | Cast Copper Alloy Fittings for Flared Copper Tubes |
B 16.28 -1994 | Wrought Steel Buttwelding Short Radius Elbows and Returns |
B 16.29 -2012 | Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings (DWV) |
B 16.34 -2013 | Valves Flanged, Threaded and Welding End |
B 16.51 -2013 | Copper and Copper Alloy Press-Connect Pressure Fittings |
BPVC Section IX-the edition referenced in rule 4101:4-3-01 of the Administrative Code | Welding and Brazing Qualifications |
Standard Referenced | Title |
1001-2008 | Performance Requirements for Atmospheric Type Vacuum Breakers |
1002-2015 | Performance Requirements for Antisiphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks |
1003-2009 | Performance Requirements for Water Pressure Reducing Valves |
1004-2008 | Performance Requirements for Backflow Prevention Requirements for Commercial Dishwashing Machines |
1005-1999 | Performance Requirements for Water Heater Drain Valves |
1008-2006 | Performance Requirements for Plumbing Aspects of Food Waste Disposer Units |
1010-2004 | Performance Requirements for Water Hammer Arresters |
1011-2004 | Performance Requirements for Hose Connection Vacuum Breakers |
1012-2009 | Performance Requirements for Backflow Preventers with Intermediate |
| Atmospheric Vent |
1013-2011 | Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers |
1015-2011 | Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies |
ASSE 1016/ ASME | Performance Requirements for Individual |
A 112.1016 / | Thermostatic, Pressure Balancing and |
CSA B 125.16 -2011 | Combination Control Valves for Individual Fixture Fittings |
1017-2010 | Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems |
1018-2010 | Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied |
1019-2011 | Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type |
1020-2004 | Performance Requirements for Pressure Vacuum Breaker Assembly |
1022-2003 | Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment |
1024-2004 | Performance Requirements for Dual Check Valve Type Backflow Preventers (for Residential Supply Service or Individual Outlets) |
1035-2008 | Performance Requirements for Laboratory Faucet Backflow Preventers |
1037-2015 | Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures |
1044-2015 | Performance Requirements for Trap Seal Primer Devices Drainage Types and Electronic Design Types |
1047-2011 | Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies |
1048-2011 | Performance Requirements for Double |
| Check Detector Fire Protection Backflow Prevention Assemblies |
1049-2009 | Performance Requirements for Individual and Branch Type Air Admittance Valves for Chemical Waste Systems |
1050-2009 | Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems |
1051-2009 | Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems-fixture and Branch Devices |
1052-2016 | Performance Requirements for Hose Connection Backflow Preventers |
1055-2009 | Performance Requirements for Chemical Dispensing Systems |
1056-2013 | Performance Requirements for Spill Resistant Vacuum Breaker |
1060-2006 | Performance Requirements for Outdoor Enclosures for Fluid Conveying Components |
1061-2015 | Performance Requirements for Removable and Nonremovable Push Fit Fittings |
1062-2006 | Performance Requirements for Temperature Actuated, Flow Reduction Valves to Individual Supply Fittings |
1066-2009 | Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings |
1069-2005 | Performance Requirements for Automatic Temperature Control Mixing Valves |
1070-2015 | Performance Requirements for Water-temperature Limiting Devices |
1072-2007 | Performance Requirements for Barrier Type Floor Drain Tap Seal Protection Devices |
1079-2012 | Performance Requirements for Dielectric Pipe Unions |
5013-2015 | Performance Requirements for Testing Reduced Pressure Principle Backflow Prevention Assembly (RPA) and Reduced Pressure Fire Protection Backflow Preventers (RFP) |
5015-2015 | Performance Requirements for Testing Double Check Valve Backflow Prevention Assemblies (DC) and Double Check Fire Protection Backflow Prevention Assemblies (DCF) |
5020-2015 | Performance Requirements for Testing Pressure Vacuum Breaker Assemblies (PVBA) |
5047-2015 | Performance Requirements for Testing Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies (RPDA) |
5048-2015 | Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA) |
5052-2015 | Performance Requirements for Testing Hose Connection Backflow Preventers |
5056-2015 | Performance Requirements for Testing Spill Resistant Vacuum Breaker (SRVB) |
Standard Referenced | Title |
A 53/A 53M-12 | Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless |
A 74-16 | Specification for Cast-iron Soil Pipe and Fittings |
A 312/A 312M-16 | Specification for Seamless, Welded, And Heavily Cold Worked Austenitic Stainless Steel Pipes |
A 733-15 | Specification for Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples |
A 778-16 | Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products |
A 888-15 | Specification for Hubless Cast-iron Soil Pipe |
| and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Application |
B 32-08 (2014) | Specification for Solder Metal |
B 42-15a | Specification for Seamless Copper Pipe, Standard Sizes |
B 43-15 | Specification for Seamless Red Brass Pipe, Standard Sizes |
B 75-11 | Specification for Seamless Copper Tube |
B 88-14 | Specification for Seamless Copper Water Tube |
B 152/B 152M-13 | Specification for Copper Sheet, Strip Plate and Rolled Bar |
B 251-10 | Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube |
B 302-12 | Specification for Threadless Copper Pipe, Standard Sizes |
B 306-13 | Specification for Copper Drainage Tube (DWV) |
B 447-12a | Specification for Welded Copper Tube |
B 687-99(2016) | Specification for Brass, Copper and Chromium-plated Pipe Nipples |
B 813-16 | Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube |
B 828-16 | Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings |
C 4-04(2014) | Specification for Clay Drain Tile and Perforated Clay Drain Tile |
C 14-15a | Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe |
C 76-15a | Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe |
C 425-04(2013) | Specification for Compression Joints for Vitrified Clay Pipe and Fittings |
C 443-12 | Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets. |
C 564-14 | Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings |
C 700-13 | Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated |
C 1053-00(2015) | Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications |
C 1173-10(2014) | Specification for Flexible Transition Couplings for Underground Piping System |
C 1277-13 | Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings |
C 1440-08(2013) | Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems |
C 1460-12 | Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground |
C 1461-08 (2013) | Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use |
C 1540-15 | Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings |
C 1563-13 | Standard Test Method for Gaskets for Use in Connection with Hub and Spigot Cast Iron Soil Pipe and Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications |
D 1253-14 | Standard Test Method For Residual Chlorine in Water |
D 1527-99(2005) | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80 |
D 1785-15 | Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120 |
D 2235-04(2011) | Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings |
D 2239-12a | Specification for Polyethylene (PE) Plastic |
| Pipe (SIDR-PR) Based on Controlled Inside Diameter |
D 2241-15 | Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series) |
D 2282-99(2005) | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) |
D 2464-15 | Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 |
D 2466-15 | Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 |
D 2467-15 | Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 |
D 2468-96a | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40 |
D 2564-12 | Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems |
D 2609-15 | Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe |
D 2657-15 | Practice for Heat Fusion-joining of Polyolefin Pipe and Fitting Waste, and Vent Pipe and Fittings |
D 2661-14 | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings |
D 2665-14 | Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings |
D 2672-14 | Specification for Joints for IPS PVC Pipe Using Solvent Cement |
D 2683-14 | Standard Specification for Socket-type Polyethylene fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing |
D 2729-11 | pecification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
D 2737-2012a | Specification for Polyethylene (PE) Plastic Tubing. |
D 2751-05 | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings |
D 2846/D 2846M-14 | Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems |
D 2855-15 | Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings |
D 2949-10 | Specification for 3.25 -in Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings |
D 3034-15 | Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
D 3035-15 | Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter |
D 3139-98(2011) | Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals |
D 3212-07 (2013) | Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals |
D 3261-15 | Specification for Butt Heat Fusion Polyethylene (PE) Plastic fittings for Polyethylene (PE) Plastic Pipe and Tubing |
D 3311-11 (2016) | Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns |
D 4068-15 | Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed Water-containment Membrane |
D 4551-12 | Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane |
E 2727-10e1 | Standard Practice for the Assessment of Rainwater Quality 1302.8.1 |
F 405-13 | Specification for Corrugated Polyethylene (PE) Pipe and Fittings |
F 409-12 | Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings |
F 437-15 | Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 |
F 438-15 | Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40 |
F 439-13 | Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 |
F 441/F 441M-15 | Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 |
F 442/F 442M-13e1 | Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) |
F 477-14 | Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe |
F 493-14 | Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings |
F 628-12e2 | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core |
F 656-15 | Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings |
F 714-2013 | Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter |
F 876-15a | Specification for Cross-linked Polyethylene (PEX) Tubing |
F 877-2011a | Specification for Cross-linked Polyethylene (PEX) Plastic Hot and Cold Water Distribution Systems |
F 891-10 | Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core |
F 1055-15 | Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene Pipe and Tubing |
F 1281-11 | Specification for Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe |
F 1282-10 | Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe |
F 1412-16 | Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage |
F 1476-13 | Standard Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications |
F 1488-14 | Specification for Coextruded Composite Pipe |
F 1548-01(2012) | Standard Specification for the Performance of Fittings for Use with Gasketed Mechanical Couplings Used in Piping Applications |
F 1673-10 | Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems |
F 1807-15 | Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing |
F 1866-13 | Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings |
F 1960-15 | Specification for Cold Expansion Fittings with PEX Reinforcing Rings for use with Cross-linked Polyethylene (PEX) Tubing |
F 1970-12e1 | Special Engineered Fittings, Appurtenances or Valves for use in Poly (Vinyl Chloride) (PVC) OR Chlorinated Poly (Vinyl Chloride) (CPVC) Systems |
F 1974-15 | Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe |
F 1986-01(2011) | Specification for Multilayer Pipe, Type 2, Compression Fittings and Compression Joints for Hot and Cold Drinking Water Systems |
F 2080-15a | Specifications for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe |
F 2098-15 | Standard specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal and Plastic Insert Fittings |
F 2159-14 | Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing |
F 2262-09 | Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9 |
F 2306/F 2306M-14e1 | 12'' to 60'' Annular Corrugated Profile-wall Polyethylene (PE) Pipe and Fittings for Gravity Flow Storm Sewer and Subsurface Drainage Applications |
F 2389-15 | Specification for Pressure-rated Polypropylene (PP) Piping Systems |
F 2434-14 | Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX AL-PEX) Tubing |
F 2735-09 | Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing |
F 2769-14 | Polyethylene or Raised Temperature (PERT) Plastic Hot and Cold Water Tubing and Distribution Systems |
F 2831-12 | Standard Practice for Internal Non Structural |
| Epoxv Barrier Coating Material Used In Rehabilitation of Metallic Pressurized Piping Systems |
F 2855-72 | Specification Polv (Vinyl ChlorideVAluminum/Polv (Vinyl Chloride) (CPVC/AL/CPVC) Composite Pressure Tubing |
Standard Referenced | Title |
A 257.1 M-2012 | Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings |
A 257.2 M-2012 | Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings |
A 257.3 M-2012 | Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets |
ASME A112.18.1-2012/ | Plumbing Supply Fittings |
CSA B 125.1 -2012 | |
A112.18.2-2015/ | Plumbing Waste Fittings |
CSA B 125.2 -2015 | |
ASME A112.19.2-2013/ | Ceramic Plumbing Fixtures |
B 45.1 -2013 | |
ASME A112.19.1-2013/ | Enameled Cast-iron and Enameled Steel |
CSA B 45.2 -2013 | Plumbing Fixtures |
ASME A112.19.3-2008/ | Stainless-steel Plumbing Fixtures |
CSA B 45.4 -08(R2013) | |
ASME A112.19.5-2011/ | Flush Valves and Spuds for Water Closets, |
CSA B 45.15 -2011 | Urinals and Tanks |
ASME A112.19.7-2012/ | Hydromassage Bathtub Systems |
CSA B 45.10 -2012 | |
CSA B 45.5 -11(R2016)/ | Plastic Plumbing Fixtures |
IAPMO Z124-2011(R2016) | |
ASME A112.3.4-2013/ | Macerating Systems and Related |
CSA B 45.9 -2013 | Components |
CSA B 125.16 -2011 | Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings |
B64.1.1-11 (2016) | Vacuum Breakers, Atmospheric Type (AVB) |
B64.1.2-11 (2016) | Pressure Vacuum Breakers, (PVB) |
B64.1.3-11 (2016) | Spill Resistant Pressure Vacuum Breaks (SRPVB) |
B 64.2 -11 (2016) | Vacuum Breakers, Hose Connection Type (HCVB) |
B64.2.1-11 (2016) | Vacuum Breakers, Hose Connection (HCVB) with Manual Draining Feature |
B64.2.1.1-11 (2016) | Hose Connection Dual Check Vacuum Breakers, (HCDVB) |
B64.2.2-11 (2016) | Vacuum Breakers, Hose Connection Type |
| (HCVB) with Automatic Draining Feature |
B 64.3 -11 (2016) | Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP) |
B 64.4 -11 (2016) | Backflow Preventers, Reduced Pressure Principle Type (RP) |
B64.4.1-11 (2016) | Reduced Pressure Principle for Fire Sprinklers (RPF) |
B 64.5 -11 (2016) | Double Check Backflow Preventers (DCVA) |
B64.5.1-11 (2016) | Double Check Valve Backflow Preventer for Fire Systems (DCVAF) |
B 64.6 -11 (2016) | Dual Check Backflow PreventersValve (DuC) |
B 64.7 -11 (2016) | Laboratory Faucet Vacuum Breakers (LFVB) |
B 64.10 -11 (2016) | Manual for the Selection and Installation of Backflow Prevention Devices |
B64.10.1-11 (2016) | Maintenance and Field Testing of Backflow Preventers |
B79-08(R2013) | Commercial and Residential Drains, and Cleanouts |
B 125.3 -2012 | Plumbing Fittings |
B 137.1 -13 | Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services |
B 137.2 -13 | Polyvinylchloride PVC Injection-moulded Gasketed Fittings for Pressure Applications |
B 137.3 -13 | Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications |
B 137.5 -13 | Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications |
B 137.6 -13 | CPVC Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems |
B 137.9 -13 | Polyethylene/Aluminum/ Polyethylene Composite Pressure Pipe Systems |
B 137.10 -13 | Cross-linked Polyethylene/Aluminum/ Polyethylene Composite Pressure Pipe Systems |
B 137.11 -13 | Polypropylene (PP-R) Pipe and Fittings for Pressure Applications |
B 181.1 -15 | Acrylonitrile-butadiene-styrene ABS Drain, |
| Waste and Vent Pipe and Pipe Fittings |
B 181.2 -15 | Polyvinylchloride PVC and chlorinated polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings |
B 181.3 -15 | Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Drainage Systems |
B 182.1 -15 | Plastic Drain and Sewer Pipe and Pipe Fittings |
B 182.2 -15 | PSM Type Polyvinylchloride PVC Sewer Pipe and Fittings |
B 182.4 -15 | Profile Polyvinylchloride PVC Sewer Pipe and Fittings |
B 182.6 -15 | Profile Polyethylene (PE) Sewer Pipe and Fittings for Leak-proof Sewer Applications |
B 182.8 -15 | Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings |
B356-10 (R2015) | Water Pressure Reducing Valves for Domestic Water Systems |
B 483.1 -14 B 481.1 -12 | Drinking Water Treatment Units Testing and Rating of Grease interceptors Using Lard |
B 481.3 -12 | Sizing, Selection, Location and Installation of Grease Interceptors |
B602-16 | Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe |