Chapter 4 of the International Plumbing
Code, 2021 edition, as incorporated by reference and modified in Section
101.1.1 of this code, is further modified as follows:
(A)
Modify
section 403.1 to add two sentences and
an exception at the end of the section to read as follows:
When the actual occupant load will be
significantly different than that determined by section 1004 of the
building code
, the
building
official
may establish an alternate
basis for determining the
occupant
load
. This alternate basis is to be
included in the special stipulations and conditions section of the certificate
of occupancy issued for that structure pursuant to section 111 of the
building code
. For accessibility requirements, see "Chapter 11,
Accessibility" of the
building
code
.
Exception:
Facilities are not required in buildings less than 100
square feet in area if fixtures are available within 500 feet of the
building.
(B)
Modify table 403.1 as follows:
Relocate the reference to footnote "f"
to the assembly classification and replace footnote "f" with the
following:
f.
The minimum required number, type and location of
plumbing fixtures for
public swimming
pools
are to be provided in accordance
with Section 3109.3.3 of the building code.
(C)
Modify the
first sentence of section
403.2 exception 6 to read as
follows:
6.
In other than Group E occupancies, separate facilities
are not required where rooms having both water closets and lavatory fixtures
are designed for use by both sexes and privacy for water closets are installed
in accordance with Section 405.3.4.
(D)
Modify
section 403.3 exception 1 to read as
follows:
(E)
Modify
section 403.3.1 as follows:
Add the phrase "or similar spaces not
available to the public" to the end of the first sentence and add two sentences
to the end of the section that read
"
The building owner is
permitted to control access to the toilet facilities. Where such access is
controlled, a sign is to be posted indicating how
access
is to be
obtained."
(F)
Replace section 403.4.1 with the
following:
403.4.1
Directional signage.
Deleted.
(G)
Add the
following sentence to the end of section 405.3.1 to read as
follows:
See Chapter 11 of the
building code
for the minimum required dimensions for accessible
fixtures.
(H)
Modify section 405.3.4 to add the following
sentence after the first sentence and before the exceptions:
Compartments of multiple-user
facilities designed to serve all genders are to comply with the Type A privacy
rating requirements of IAPMO/ANSI/CAN Z124.10.
(I)
Replace
section 405.7 with the
following:
405.7
Plumbing in mental health centers.
Deleted.
(J)
Replace the
first sentence of section 410.3.1 to read as follows:
Where
drinking fountains
are required, not fewer than two
drinking fountains
are to be provided.
(K)
Replace the
last sentence in section
410.4 to read as
follows:
In other occupancies where
water dispensers
are provided,
drinking fountains
are not required to be installed.
(L)
Modify
section 421.5.2 to add exception #3 to read as follows:
3.
The shower liner
test is not required for one-, two-, or three-family dwellings unless required
by the shower liner manufacturer's installation instructions.
Replaces: 4101:3-4-01
Notes
Ohio Admin. Code
4101:3-4-01
Effective:
3/1/2024
Five Year Review (FYR) Dates:
03/01/2029
Promulgated
Under: 119.03
Statutory Authority: 3781.10(A)(1), 3781.109(A)
Rule Amplifies: 3781.10, 3781.11, 3791.04
Prior
Effective Dates: 03/01/1998, 04/01/1999, 01/01/2002, 01/01/2003, 08/15/2003,
03/01/2005, 09/06/2005, 03/01/2006, 07/01/2007, 11/01/2007, 01/01/2009,
11/01/2011, 07/01/2014, 01/01/2016,
11/01/2017