25 Pa. Code § 289.531 - Scope and requirements
(a) A
person or municipality operating a Class II residual waste disposal impoundment
shall design, construct, operate and maintain a liner system for disposal areas
of the facility or components thereof in accordance with this section and
§§ 289.532-289.538.
(b)
The liner system for a Class II residual waste disposal impoundment shall
include the following elements:
(1) The
subbase, which is the prepared layer of soil or earthen material upon which the
remainder of the liner system is constructed.
(2) The leachate detection zone, which is a
prepared layer placed on top of the subbase and upon which the liner is placed,
and in which a leachate detection system is located.
(3) The composite liner, which is a
continuous layer of synthetic material over earthen material, placed on the
leachate detection zone.
(4) The
protective cover and leachate collection zone, which is a prepared layer placed
over the liner in which a leachate collection system is located.
Notes
This section cited in 25 Pa. Code § 287.114 (relating to interim operational requirements for unpermitted processing or disposal facilities); 25 Pa. Code § 287.116 (relating to interim operational requirements); 25 Pa. Code § 289.512 (relating to liner system and leachate control plan); and 25 Pa. Code § 289.521 (relating to limitations).