34 Pa. Code § 58.21 - Minimum exits

(a) There shall be a minimum of two exits reasonably remote from each other, except that one story buildings 1,200 square feet or less may have one exit. At least 50% of all required exits shall be exit discharge doors to the outside, stair towers or ramps.
(b) Basements used only for storage or mechanical equipment without any permanent occupancy shall have a minimum of two exit access paths except that the Department may permit a single exit access for basements less than 1,000 square feet used only for storage or mechanical equipment without any permanent occupancy.
(c) Mezzanine levels shall have a minimum of two exit access paths except that the Department may permit a single exit access from mezzanines less than 1,000 square feet or mezzanines used exclusively for storage or mechanical equipment without a permanent occupancy.