(1) Applicability
of this rule is as follows:
(a) This rule
applies to the following process sections at facilities in Davidson,
Rutherford, Shelby, Sumner, Williamson, and Wilson Counties engaged in the
manufacture of high-density polyethylene, polypropylene, and polystyrene:
1. For the manufacture of high-density
polyethylene using a liquid-phase slurry process: each material recovery
section and each product finishing section;
2. For the manufacture of polypropylene using
a liquid-phase process: each polymerization reaction section, each material
recovery section, and each product finishing section; and
3. For the manufacture of polystyrene using a
continuous process: each material recovery section.
(b) Facilities having all process sections
with uncontrolled emission rates at or below those identified as follow are
exempt from the requirements of this rule except that owners or operators
seeking to comply with this rule by complying with the uncontrolled emission
rates in this subparagraph are still required to comply with the initial
certification requirements at Paragraph .04(1) of this chapter:
Uncontrolled emission rate, megagram of product per
Production Process |
Process Section |
year (Mg/yr) |
1. High density polyethylene,
liquid-phase slurry process. |
material recovery
section |
7 |
2. High density polyethylene,
liquid-phase slurry process |
product finishing
section |
19 |
3. Polypropylene, liquid-phase
process |
polymerization reaction section |
7 |
4. Polypropylene, liquid-phase
process |
material recovery section |
8 |
5. Polypropylene, liquid-phase
process |
product finishing section |
36 |
6. Polystyrene, continuous
process |
material recovery section |
7 |
(2) For the purpose of this rule, the
following definitions apply:
(a) "Continuous
process" means a polymerization process in which reactants are introduced in a
continuous manner and products are removed either continuously or
intermittently at regular intervals so that the process can be operated and
polymers produced essentially continuously.
(b) "Flame zone" means that portion of the
combustion chamber in a boiler occupied by the flame envelope.
(c) "High-density polyethylene" means a
linear, thermoplastic polymer comprised of at least 50 percent ethylene by
weight and having a density greater than 0.94 grams per cubic centimeter
(g/cm3) (59 pounds per cubic foot
[lb/ft3 ]).
(d) "Liquid-phase process" means a
polymerization process in which the polymerization reaction is carried out in
the liquid phase; i.e.,the monomer(s) and any catalyst are dissolved or
suspended in a liquid solvent.
(e)
"Liquid-phase slurry process" means a liquid-phase polymerization process in
which the monomer(s) are in solution (completely dissolved) in a liquid
solvent, but the polymer is in the form of solid particles suspended in the
liquid reaction mixture during the polymerization reaction, sometimes called a
particle-form process.
(f)
"Polypropylene" means a polymer comprised of at least 50 percent propylene by
weight.
(g) "Polystyrene" means a
thermoplastic polymer comprised of at least 80 percent stryene or
para-methylstyrene by weight.
(h)
"Process line" means a group of equipment assembled that can operate
independently if supplied with sufficient raw materials to produce
polypropylene, high-density polyethylene, polystyrene. A process line consists
of the equipment in the following process sections (to the extent that these
process sections are present at a plant): raw materials preparation,
polymerization reaction, product finishing, product storage, and material
recovery.
(i) "Process section"
means the equipment designed to accomplish a general but well-defined task in
polymer production. Process sections include raw materials preparation,
polymerization reaction, material recovery, product finishing, and product
storage and may be dedicated to a single process line or common to more than
one process line.
(j) "Product
finishing section" means the equipment that treats, shapes, or modifies the
polymer or resin to produce the finished end product of the particular
facility. Product finishing equipment may accomplish extruding and pelletizing,
cooling and drying, blending, additives introduction, curing, or annealing.
Product finishing does not include polymerization or shaping such as fiber
spinning, molding, or fabricating or modification such as fiber stretching and
crimping.
(3) The owner
or operator of a high-density polyethylene or polypropylene process line
containing a process section subject to this rule shall comply with the
following:
(a) Reduce emissions of total
volatile organic compounds (VOC's) by 98 weight percent, determined according
to the procedure specified in Subparagraph (5)(a) of this rule, or to a VOC
concentration of 20 parts per million volumetric (ppmv), as determined by the
procedure specified in Subparagraph (5)(b) of this rule, on a dry basis,
whichever is less stringent. Total VOC is expressed as the sum of the actual
compounds, not carbon equivalents. If an owner or operator elects to comply
with the 20 ppmv concentration standard, the concentration shall include a
correction to 3 percent oxygen only when supplemental combustion air is used to
combust the vent stream. The procedure in Subparagraph (5)(c) shall be used to
correct the concentration to 3 percent oxygen;
(b) Combust the emissions in a boiler or
process heater with a design heat input capacity of 150 million British thermal
units per hour (Btu/hr) or greater by introducing the vent stream into the
flame zone of the boiler or process heater; or
(c) Combust the emissions in a flare as
follows:
1. Flares shall be designed for and
operated with no visible emissions as determined by the method specified in
Part (5)(d)1 of this rule, except for periods not to exceed a total of 5
minutes during any 2 consecutive hours;
2. Flares shall be operated with a flame
present at all times, as determined by the method specified in Part (5)(d)2 of
this rule;
3. Flares used to comply
with provisions of this rule shall be steam-assisted, air-assisted, or
non-assisted;
4. Flares shall be
used only with the net heating value of the gas being combusted being 11.2
megaJoules per standard cubic meter (MJ/scm) (300 Btu per standard cubic foot
[Btu/scf]) or greater if the flare is steam-assisted or air-assisted; or with
the net heating value of the gas being combusted being 7.45 MJ/scm (200
Btu/scf) or greater if the flare is non-assisted. The net heating value of the
gas being combusted shall be determined by the method specified in Part (5)(e)7
of this rule.
5. Consistent with
exit velocity requirements as follow:
(i)
Steam-assisted and non-assisted flares shall be designed for and operated with
an exit velocity, as determined by the method specified in Part (5)(e) 4 of
this rule, less than 18.3 meters per second (m/s) (60 feet per second [ft/s]),
except as provided in Subparts (ii) and (iii) of this part;
(ii) Steam-assisted and non-assisted flares
designed for and operated with an exit velocity, as determined by the methods
specified in Part (5)(e)4 of this rule, equal to or greater than 18.3 m/s (60
ft/s) but less than 122 m/s (400 ft/s) are allowed if the net heating value of
the gas being combusted is greater than 37.3 MJ/scm (1,000 Btu/scf);
and
(iii) Steam-assisted and
non-assisted flares designed for and operated with an exit velocity, as
determined by the methods specified in Part (5)(e)4 of this rule, less than the
velocity, Vmax, as determined by the method specified in
Part (5)(e)5 of this rule and less than 122 m/s (400 ft/s) are
allowed.
6. Air-assisted
flares shall be designed and operated with an exit velocity less than the
velocity, Vmax, as determined by the method specified in
Part (5)(e)6 of this rule.
(4) The owner or operator of a polystyrene
process line containing process sections subject to this rule shall comply with
the following:
(a) Not allow continuous VOC
emissions from the material recovery section to be greater than 0.12 kg
(kilograms) VOC per 1,000 kg of product (0.12 pounds [lb] VOC per 1,000 lb of
product); or
(b) Not allow the
outlet gas stream from each final condenser in the material recovery section to
exceed -25°C (-13°F).
(5) Test methods and procedures as follow
apply:
(a) The owner or operator shall
determine compliance with the percent emission reduction standard in
Subparagraph (3)(a) of this rule as follows:
1. The emission reduction of total VOC shall
be determined using the following equation:
Click
to view Image
where:
P = Percent emission reduction, by weight.
Einlet = Mass rate of total VOC
entering the control device, kg VOC/hr.
Eoutlet = Mass rate of total VOC
discharged to the atmosphere, kg VOC/hr.
2. The mass rates of total VOC
(E
i , E
o) shall be computed
using the following equations:
Click
to view Image
Click
to view Image
where:
Cij , Coj =
Concentration of sample component "j" of the gas stream at the inlet and outlet
of the control device, respectively, dry basis, ppmv.
Mij , Moj =
Molecular weight of sample component "j" of the gas stream at the inlet and
outlet of the control device respectively, g/gmole (lb/lb-mole).
Qi , Qo = Flow
rate of the gas stream at the inlet and outlet of the control device,
respectively, dscm/hr (dscf/hr).
K = 4.157 x 10-8
[(kg)/(g-mole)]/[(g)(ppm)(dscm)] or {2.595 x 10-9
[(lb)(/(lb-1 mole)]/[(lb)(ppm)(dscf)]}.
3. Reference Method 18 shall be used to
determine the concentration of each individual organic component
(Cij , Coj) in the gas stream.
Reference Method 1 or 1A, as appropriate, shall be used to determine the inlet
and outlet sampling sites. The inlet site shall be before the inlet of the
control device and after all product recovery units.
4. Reference Method 2, 2A, 2C, or 2D, as
appropriate, shall be used to determine the volumetric flow rates
(Qi , Qo). If necessary, Method 4
shall be used to determine the moisture content. Both determinations shall be
compatible with the Reference Method 18 determinations.
5. Inlet and outlet samples shall be taken
simultaneously. The sampling time for each run shall be 1 hour in which either
an integrated sample or four grab samples shall be taken. If grab sampling is
used, then the samples shall be taken at 15 minute intervals.
(b) The owner or operator shall
determine compliance with the emission concentration standard in Subparagraph
(3)(a) of this rule as follows:
1. The total
VOC concentration is the sum of the individual components and shall be computed
for each run using the following equation:
Click
to view Image
where:
Cvoc = Concentration of total VOC, dry
basis, ppmv;
Cj = Concentration of sample
component j, ppm; and
n = Number of components in the sample.
2. Reference Method 18 shall be used to
determine the concentration of each individual inorganic component
(Cj) in the gas stream. Reference Method 1 or 1A as
appropriate, shall be used to determine the sampling site at the outlet of the
control device. Reference Method 4 shall be used to determine the moisture
content, if necessary.
3. The
sampling time for each run shall be 1 hour in which either an integrated sample
or four grab samples shall be taken. If grab sampling is used, then the samples
shall be taken at 15 minute intervals.
(c) Correction for supplemental combustion
air shall be as follows:
1. If supplemental
combustion air is used, the total VOC concentration shall be corrected to 3
percent oxygen and shall be computed using the following equation:
Click
to view Image
CCORR = Concentration of total VOC
corrected to 3 percent oxygen, dry basis, ppmv;
CMEAS = Concentration of total VOC,
dry basis, ppmv, as calculated in Part (5)(b)1 above; and
%O2d = Concentration of
O2 , dry basis, percent by volume.
2. The emission rate correction factor,
integrated sampling and analysis procedure of Reference Method 3 shall be used
to determine the oxygen concentration (%O) . The sampling site shall be the
same as that of the total VOC sample 2d and the samples shall be taken during
the same time that the total VOC samples are taken.
(d) When a flare is used to comply with
Subparagraph (3)(c) of this rule:
1.
Reference Method 22 shall be used to determine the compliance of flares with
the visible emission requirement in Part (3)(c)1 of this rule. The observation
period is 2 hours and shall be used according to Reference Method 22;
and
2. The presence of a flare
pilot flame shall be monitored using a thermocouple or other equivalent
monitoring device to detect the presence of a flame.
(e) The test methods shall be used for
determining the VOC emission rate in terms of kg emission per megagram (Mg) of
product, exit velocities, or net heating value of the gas combusted to
determine compliance under Paragraphs (3) and (4) of this rule as follows:
1. Reference Method 1 or 1A, as appropriate,
for selection of the sampling site. The sampling site for the molar composition
and vent stream flow rate determination prescribed in Parts 2 and 3 of this
subparagraph shall be prior to the inlet of any combustion device and prior to
any dilution of the stream with air.
2. The composition of the process vent stream
shall be determined as follows:
(i) Reference
Method 18 and ASTM D2504-67 (reapproved 1977) to measure the concentration of
VOC and the concentration of all other compounds present except water vapor and
carbon monoxide, and
(ii) Reference
Method 4 to measure the content of water vapor.
3. The volumetric flow rate shall be
determined using Reference Method 2, 2A, 2C, or 2D, as appropriate;
4. The actual exit velocity of a flare shall
be determined by dividing the volumetric flow rate (in units of standard
temperature and pressure), as determined by Reference Method 2, 2A, 2C, or 2D
as appropriate, by the unobstructed (free) cross-sectional area of the flare
tip;
5. The maximum permitted
velocity, V , for flares complying with Subpart max (3)(c)5(i) of this rule
shall be determined using the following equation:
Click
to view Image
where:
Vmax = Maximum permitted velocity,
m/s;
28.8 = Constant;
31.7 = Constant; and
HT = The net heating value as
determined in Part 7 of this subparagraph.
6. The Vmax for air-assisted flares shall be
determined by the following equation:
Vmax = 8.706 + 0.7084 (HT) where:
Vmax = Maximum permitted velocity, m/s;
8.706 = Constant;
0.7084 = Constant; and
HT = The net heating value as determined in Part 7 of this
subparagraph.
7. The net
heating value of the process vent stream being combusted in a flare shall be
calculated using the following equation:
HT = K SUM CinHi i = 1
where:
HT = Net heating value of the sample, MJ/scm, where the net
enthalpy per mole of offgas is based on combustion at
250C and 760 millimeters of Mercury (mm Hg)
(770F and 29.92 inches of Mercury [in Hg]), but the
standard temperature for determining the volume corresponding to one mole is
200C (680F);
K = Constant:
Click
to view Image
where standard temperature for (g mole)/scm is 200C.
Ci = Concentration of sample components i in ppm on a wet
basis, as measured for organics by Reference Method 18 and measured for
hydrogen and carbon monoxide by ASTM D1946-82; and
Hi = Net heat of combustion of sample component i,
kcal/g-mole at 25°C (77°F) and 760 mm Hg (29.92 in Hg). The heats of
combustion of process vent stream components may be determined using ASTM
D2382-76 (reapproved 1977) if published values are not available or cannot be
calculated;8.The emission rate of VOC in the process vent stream shall be
calculated using the following equation:
8. The emission rate of VOC in the process
vent stream shall be calculated using the following equation:
Click
to view Image
where:
Evoc= Emission rate of total organic
compounds in the sample, kilogram per hour (kg/h);
K = Constant, 2.494 x 10-6
(1/ppm)(g-mole/scm)(kg/g)(min/h), where standard temperature for (g-mole/scm)
is 20°C (68°F);
Ci = Concentration of sample component
i, ppm;
Mi = Molecular weight of sample
component i, g/g-mole; and
Q = Vent stream flow rate (scm/min), at a standard
temperature of 20°C s (68°F) .
9. The rate of polymer produced,
Pp (kg/h), shall be determined by dividing the weight of
polymer pulled in kg from the process line during the performance test by the
number of hours (h) taken to perform the performance test. The polymer pulled,
in kg, shall be determined by direct measurement or, if approved by the
Technical Secretary and approved as a revision to the State Implementation
Plant, computed from materials balance by good engineering practice;
and
10. The emission rate of VOC in
terms of kilograms of emissions per megagram of production shall be calculated
using the following equation:
Click
to view Image
where:
ER = Emission rate of VOC, kg VOC/Mg product; voc
E = Emission rate of VOC in the sample, kg/h; and voc
P = The rate of polymer produced, kg/h. p
(6) The owner or
operator of a facility subject to this rule shall maintain the following
records for at least 3 years and shall make these records available to the
Technical Secretary upon request:
(a) For
facilities complying with the standards listed in Subparagraph (3)(a),
parameters listed in Subparagraphs (5)(a), (5)(b), and, where applicable,
(5)(e);
(b) For facilities
complying with the standards listed in Subparagraph (3)(b), parameters listed
in Subparagraphs (5)(c), and, where applicable, (5)(e);
(c) For facilities complying with the
standards listed in Subparagraph (3)(c), parameters listed in Subparagraphs
(5)(d), and, where applicable, (5)(e);
(d) For facilities complying with the
standards listed in Paragraph (4), parameters listed in Subparagraph (5)(e)
where applicable; and
(e) For all
facilities containing sources subject to this rule, the following records shall
be kept:
1. The time, date, and duration of
any excess emissions;
2. The
subject source of any excess emissions;
3. The cause of any excess
emissions;
4. The estimated rate of
emissions (expressed in the units of the applicable emission limitation) and
the operating data and the calculations used in determining the magnitude of
any excess emissions; and
5. Any
corrective actions and schedules utilized to correct the conditions causing any
excess emissions.
(7) The owner or operator of any facility
containing sources subject to this rule shall:
(a) Comply with the initial compliance
certification requirements of Paragraph .04(1) of this chapter; and
(b) Comply with the requirements of Paragraph
.04(2) of this chapter for excess emissions related to the control devices
required to comply with Subparagraph (3)(b), (3)(c), or (4)(b) of this
rule.