Utah Admin. Code R315-264-194 - General Operating Requirements
(a) Hazardous wastes or treatment reagents
shall not be placed in a tank system if they could cause the tank, its
ancillary equipment, or the containment system to rupture, leak, corrode, or
otherwise fail.
(b) The owner or
operator shall use appropriate controls and practices to prevent spills and
overflows from tank or containment systems. These include at a minimum:
(1) Spill prevention controls, e.g., check
valves, dry disconnect couplings;
(2) Overfill prevention controls, e.g., level
sensing devices, high level alarms, automatic feed cutoff, or bypass to a
standby tank; and
(3) Maintenance
of sufficient freeboard in uncovered tanks to prevent overtopping by wave or
wind action or by precipitation.
(c) The owner or operator shall comply with
the requirements of Section
R315-264-196
if a leak or spill occurs in the tank system.