Wash. Admin. Code § 246-215-05285 - Operation and maintenance-Water reservoir of fogging devices, cleaning (FDA Food Code 5-205.14)
(1) A
reservoir that is used to supply water to a device such as a produce fogger
must be:
(a) Maintained in accordance with
manufacturer's specifications; and
(b) Cleaned in accordance with manufacturer's
specifications or according to the procedures specified under subsection (2) of
this section, whichever is more stringent.
(2) Cleaning procedures must include at least
the following steps and must be conducted at least once a week:
(a) Draining and complete disassembly of the
water and aerosol contact parts;
(b) Brush cleaning the reservoir, aerosol
tubing, and discharge nozzles with a suitable detergent solution;
(c) Flushing the complete system with water
to remove the detergent solution and particulate accumulation; and
(d) Rinsing by immersing, spraying, or
swabbing the reservoir, aerosol tubing, and discharge nozzles with at least 50
mg/L hypochlorite solution.
Notes
Statutory Authority: RCW 43.20.050 and 43.20.145. 13-03-109, § 246-215-05285, filed 1/17/13, effective 5/1/13.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.