Wash. Admin. Code § 246-359-500 - Window construction requirements
(1) All habitable rooms and spaces must be
provided with windows the total area of which must be not less than one-tenth
of the floor area.
(2) At least
one-half of each required window must be able to open for ventilation
purposes.
(3) Every sleeping room
must have at least one operable window or door for emergency escape or rescue
directly opening to an outside area to provide a clear escape away from the
building.
(4) Escape or rescue
windows must have:
(a) A minimum net clear
openable area of five point seven square feet; and
(b) A finished sill height not more than
forty-four inches above the floor.
(c) The following minimum net clear openable
dimensions:
(i) The height dimension of
twenty-four inches; and
(ii) The
width dimension of twenty inches.
(5) All operable window openings must be
screened with sixteen-mesh material.