Wash. Admin. Code § 296-78-84001 - Loading, piling, storage and conveying-General
(1) Units or loads of lumber built up for
transportation by overhead cranes, lift trucks, auto trucks, or manually or
mechanically operated transfers must be provided with at least one set of
stickers for each eighteen inches in height of unit or load. One set of
stickers must be not more than six inches from the top of units of lumber up to
three inch dimension. Where dimension of material is greater than three inches,
a set of stickers must be placed under the top layer. Stickers must extend the
full width of the package, must be uniformly spaced, and must be aligned one
above the other. Stickers may be lapped with a minimum overlapping of twelve
inches. Stickers must not protrude more than two inches beyond the sides of the
package.
(2) Lumber loading. Loads
must be built and secured to insure stability in transit.
(3) Units or loads of lumber must not be
lifted or moved until all workers are in the clear.
(4) Gradient of roll sets or roll cases over
which units of lumber are to be moved must not exceed three percent. The
movement of units must be under control at all times.
(5) Stacking of lumber in yards, either by
units or in block piles, must be conducted in a safe and orderly
manner.
(6) Foundations for piling
lumber in yards must be capable of supporting the maximum applied load without
tipping or sagging.
(7) The height
of stacked units in storage areas must not exceed seven of the usual four foot
units, subject to the following qualifications:
(a) Units of lumber must not be stacked more
than four high unless two or more stacks of units are tied together with
ties.
(b) Long units of lumber must
not be stacked upon shorter packages except where a stable pile can be made
with the use of package separators.
(c) In unit package piles, substantial
polsters or unit separators must be placed between each package directly over
the stickers.
(8) Wooden
horses used for loading preformed loads of lumber must be of material not less
than four by six inches in cross section net measure.
(9) Unstable piles. Piles of lumber which
have become unstable must be immediately made stable or removed.
(10) Lift boards or pallets must be loaded in
such a manner as to prevent material from spilling or the material must be
secured with a binder.
(11) Packing
rooms must be kept free of debris and chutes must be equipped with a means of
slowing down the materials.
(12)
Sorting chains must be provided with a stopping device which must be readily
accessible at all times to at least one employee working on the
chain.
(13) The inside of the
walkway of all green chains and sorting tables shall be provided with a
standard toeboard.
(14) Rollers or
other devices must be provided for removing heavy dimension lumber from the
cabin or table.
(15) Roll casings
and transfer tables must be cleaned regularly and kept reasonably free from
debris.
(16) In all permanent
installations, green chains and sorting tables must be roofed over to provide
protection from inclement weather. Normal work stations must be provided with a
drained work surface which is evenly floored of nonslip material.
(17) Power driven rolls must be operated in a
manner to prevent end collisions.
(18) The space between live rolls must be
filled in on either side of crosswalks with material of structural strength to
withstand the load imposed with a four to one safety factor.
(19) The driving mechanism of live rolls must
be guarded wherever exposed to contact.
(20) Live rolls must be replaced when their
surface develops a break or hole.
(21) Guarding. Spiked live rolls must be
guarded.
(22) Ramps or skidways
used to transfer lumber or materials from one level to another must be provided
with all safeguards necessary for the protection of workers.
(23) Landings on a lower level where lumber
or timbers are discharged over ramps or skidways must be provided with a solid
bumper not less than six inches in height at the outer edge. Such landing must
be maintained in good repair at all times.
(24) Ramps or skidways must be arranged so
that the person putting lumber down has a clear view of the lower landing.
Lumber or timbers must not be put down until all workers are in the
clear.
(25) The under face of all
ramp or skidway landings must be fenced off or other positive means provided to
prevent persons from walking out under dropping timber.
(26) Return strands of sorting table ramp
chains must be supported by troughs of sufficient strength to support the
weight of a broken chain.
Notes
Statutory Authority: RCW 49.17.040, 49.17.050 and 49.17.240. 81-18-029 (Order 81-21), § 296-78-84001, filed 8/27/81.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.