Wash. Admin. Code § 296-803-50010 - Meet these requirements when applying lockout or tagout devices
(1) You must make
sure, before a machine or equipment is turned off, that the authorized employee
knows all of the following:
(a)
Type and magnitude of the energy.
(b) Hazards of the energy to be
controlled.
(c) Method or means to
control the energy.
(2)
You must turn off or shut down the machine or equipment using established
procedures. An orderly shut down is necessary to avoid any additional or
increased hazard to employees as a result of the equipment stoppage.
(3) You must completely isolate the machine
or equipment from its energy sources using the appropriate energy-isolating
devices after the machine or equipment has been turned off.
(4) You must make sure you or the authorized
employee notify affected employees that the machine or equipment is being
locked or tagged out before the devices are applied.
(5) You must make sure a lockout or tagout
device is applied:
(a) For each
energy-isolating device.
(b) Only
by the authorized employee doing the service or maintenance.
Notes
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 09-16-108, § 296-803-50010, filed 8/4/09, effective 11/1/09; 04-15-105, § 296-803-50010, filed 7/20/04, effective 11/1/04.