Wash. Admin. Code § 468-240-205 - Obstruction lighting standards - Water towers, grain elevators, gas holders and similar obstructions
Water towers, grain elevators, gas holders and similar obstructions should be lighted in accordance with the following specifications:
(1)
Specification "G-1." When the particular obstruction is not more
than 150 feet in over-all height above ground, or water if so situated.
(a) There should be installed at the top of
the obstruction at least two lights, each light consisting of a lamp of at
least 100 watts, enclosed in aviation red obstruction light globes. These
lights should burn simultaneously and should be positioned so as to insure
unobstructed visibility of at least one of the lights from aircraft at any
normal angle of approach.
(2)
Specification "G-2." When
the particular obstruction is more than 150 feet but not more than 300 feet in
over-all height above ground, or water if so situated.
(a) There should be installed at the top of
the obstruction a flashing 300 mm electric code beacon equipped with two lamps
and aviation red color filters. The two lamps of the beacon should burn
simultaneously and each should be at least 500 watts. The beacon should be
positioned so as to insure unobstructed visibility of it from aircraft at any
normal angle of approach.
(b) At
the approximate midpoint of the over-all height of the obstruction, there
should be installed three or more lights, each light consisting of a lamp of at
least 100 watts, enclosed in aviation red obstruction light globes. The
position of these intermediate lights on the vertical plane should be as close
to an equidistant level between the top beacon and the ground level as the
particular shape and type of construction of the obstruction will permit. These
lights should be placed at regular intervals on the horizontal plane in a
manner to insure unobstructed visibility of at least two of the lights from
aircraft at any normal angle of approach.
(3)
Specification "G-3." When
the particular obstruction is more than 300 feet but not more than 450 feet in
over-all height above ground, or water if so situated.
(a) There should be installed at the top of
the obstruction a flashing 300 mm electric code beacon equipped with two lamps
and aviation red color filters. The two lamps of the beacon should burn
simultaneously and each should be at least 500 watts. The beacon should be
positioned so as to insure unobstructed visibility of it from aircraft at any
normal angle of approach.
(b) At
approximately two-thirds and one-third of the over-all height of the
obstruction there should be installed three or more lights, each light
consisting of a lamp of at least 100 watts, enclosed in aviation red
obstruction light globes. The position of these intermediate lights on the
vertical plane should be as close to equidistant positions between the top
beacon and the ground level as the particular shape and type of construction of
the structure will permit. These lights should be placed at regular intervals
on the horizontal plane in a manner to insure unobstructed visibility of at
least two lights on each level from aircraft at any normal angle of
approach.