Wash. Admin. Code § 51-11C-402142 - Table C402.1.4.2-Effective R-values for steel stud wall assemblies

Table C402.1.4.2 Effective R-values For Steel Stud Wall Assemblies

NOMINAL STUD DEPTH (inches)

SPACING OF FRAMING (inches)

CAVITY R-VALUE (insulation)

CORRECTION FACTOR (Fc)

EFFECTIVE R-VALUE (ER)(Cavity R-Value × Fc)

3 1/2

16

13

0.46

5.98

15

0.43

6.45

3 1/2

24

13

0.55

7.15

15

0.52

7.80

6

16

19

0.37

7.03

21

0.35

7.35

6

24

19

0.45

8.55

21

0.43

9.03

8

16

25

0.31

7.75

24

25

0.38

9.50