Wash. Admin. Code § 51-11C-40227 - Section C402.2.7-Airspaces
EXCEPTION: |
The thermal resistance of airspaces located on the exterior side of the continuous air barrier and adjacent to and behind the exterior wall covering material shall be determined in accordance with ASTM C1363 modified with an airflow entering the bottom and exiting the top of the airspace at a minimum air movement rate of not less than 70 mm/sec. |