Wash. Admin. Code § 51-11C-405053 - Table C405.4.2(1)-Interior lighting power allowances-Building area method

Table C405.4.2(1)

Interior Lighting Power Allowances-Building Area Method

Building Area Type

LPD (w/ ft2)

Automotive facility

0.64

Convention center

0.64

Court house

0.79

Dining: Bar lounge/leisure

0.79

Dining: Cafeteria/fast food

0.72

Dining: Family

0.71

Dormitory

0.46

Exercise center

0.67

Fire station

0.54

Gymnasium

0.75

Health care clinic

0.70

Hospital

0.84

Hotel/motel

0.56

Library

0.83

Manufacturing facility

0.82

Motion picture theater

0.44

Multiple family

0.41

Museum

0.55

Office

0.64

Parking garage

0.14

Penitentiary

0.65

Performing arts theater

0.84

Police station

0.66

Post office

0.65

Religious building

0.67

Retail

0.84

School/university

0.70

Sports arena

0.62

Town hall

0.69

Transportation

0.50

Warehouse

0.40

Workshop

0.91